9. Specifications (continued)

ENVIRONMENT

Temperature

Humidity

Altitude

Orientation

Mechanical

shock

Vibration

Non operating: -40 to +72

°

C

Note:  High temperature for prolonged duration will shorten the battery life.

Operating:   0  to +52

°

C.

Up to 95%. Over-sized, drip-proof front panel.

Operating: Up to 10,000 feet.

Non-operating:  (Air transport)  40,000 feet.

May be installed at any orientation.

When packed, withstands the free fall drop and edgewise drop IAW

Methods 5007.1 and 5008.1 of Federal Test Method standard 101C.

When  operating, withstands the high-impact shipboard shock IAW

MIL-S-901D, grade A, class  II., Type B.

When operating, withstands Type I vibration IAW MIL-STD-167-1. The

UPS will endure a sweep of 1.5g sinusoidal vibration from 5 to 50 Hz for a

total duration of 2 hours, and random vibration IAW MIL-STD-810D,  Cat.

9, Proc. I (test condition I-3.2.11, Fig. 514.3-34)

INDICATIONS
& CONTROLS

a) Visual

Indications

(Front panel)

b) Test Mode

c)  Audible

Alarm

d) Power

Switches

e) Remote

ON/OFF

10-segment tri-color Bar Graph for load level display.

10-segment Bar Graph for battery charge level display.

"Output OK", "Output Fail" and “Standby” status lamps.

"Input OK"  and "Input Fail" status lamps.

"On Batt " status lamp.

"Batt Passed" and "Batt Failed" lamps for  battery  self-test.

"Low Batt" warning lamp.

"Overload  Shutdown"  status lamp.

"Overtemp warning" and "Overtemp Shutdown" lamps.

When test mode is invoked by pressing the push-button on the front panel,

the UPS performs battery impedance testing without interrupting the output

power  (even if the battery fails) utilizing a proprietary time-sharing circuit.

The test results are displayed on  panel indicators.

End-to-End testing of the UPS is accomplished by cycling the INPUT

ON/OFF switch on the front panel.

The UPS will beep when it operates on battery power or during over-

temperature condition.  The alarm may be silenced by pressing the "Alarm

Off" push-button on the front panel.

The 

PTC-0

110BA-2 has two double-pole contactors, one on the input and 

one on 

the output.

The input ON/OFF contactor is controlled by the input ON/OFF switch

located on the front panel.

The Master ON/OFF switch, located on the front panel, shuts down the UPS

and opens both input and output contactors when in the OFF position.

 When the two ON/OFF pins are opened the UPS will turn OFF and the

input and output contactors will open. When the two lines are shorted

together the front panel switches determine the status. (The UPS is supplied

with a mating connector and a jumper between the two ON/OFF pins).

Summary of Contents for PTC-0110BA-2

Page 1: ...g Company AG UNINTERRUPTIBLE POWER SYSTEM 400Hz IN 60Hz OUT SINGLE PHASE 1kW 2kVA PTC 0110BA 2 MADE IN THE U S A USER S MANUAL P T C Production Trading Co AG P O Box CH 6330 Cham Switzerland Phone 41...

Page 2: ...8 6 3 Battery Test 9 7 Taking Care of the Battery 9 7 1 Battery Service Life 9 7 2 Replacing the Battery Pack 10 8 Communications and Remote Control 11 8 1 Dry Contacts Interface 11 8 1 1 Option 0 St...

Page 3: ...do not turn off the UPS The unit should only be plugged into an approved double pole and fused 20A electrical outlet The Replaceable Battery Pack of the 37 110BA 2 P N M357380 contains lead acid batte...

Page 4: ...microcontroller based Control Circuit The AC DC Converter is a high frequency switching converter that provides 320VDC to the DC AC inverter The AC DC converter draws clean sine input current waveform...

Page 5: ...ILTER VARISTOR AC DC CONVERTER DC AC INVERTER CONTROL MONITOR BATTERY CHARGER BATTERY PACK 24VDC 24VRTN INPUT ON OFF SWITCH MASTER ON OFF SWITCH REMOTE ON OFF SWITCH 2 POLES INPUT CONTACTOR 2 POLES OU...

Page 6: ...1 is the input connector J2 is the output of the UPS Figure 2 below shows the electrical power connections of the 37 110BA 2 After the unit is installed and ready to be turned ON see paragraph 6 1 Tur...

Page 7: ...ts See Figure 3 1 Removable air filter of the Power Conditioner s cooling air 2 Visual Indicators and Switches for detailed view see Figure 4 3 Air Inlet of main UPS heatsink 4 Input ON OFF Switch 5 M...

Page 8: ...ellow 12 Alarm Off Push button 13 Low Battery Warning LED blinking yellow 14 Overload Shutdown LED red 15 Overtemperature Warning LED blinking yellow 16 Overtemperature Shutdown LED red 17 Load Level...

Page 9: ...sition Turning the remote ON OFF switch ON and OFF will turn the UPS ON and OFF Please see paragraph 8 3 6 2 Visual Indicators 6 2 1 Normal Operation When the UPS is running on AC input power and both...

Page 10: ...sition Turning the remote ON OFF switch ON and OFF will turn the UPS ON and OFF Please see paragraph 8 3 6 2 Visual Indicators 6 2 1 Normal Operation When the UPS is running on AC input power and both...

Page 11: ...do not turn off the UPS The unit should only be plugged into an approved double pole and fused 20A electrical outlet The Replaceable Battery Pack of the 37 110BA 2 P N M357380 contains lead acid batte...

Page 12: ...ertheless it is a Limited Life Item and its life expectancy depends upon its operating and storage conditions The three most important factors that determine the life of the battery are Temperature St...

Page 13: ...ector access cover Remove screws e Disconnect the connector by pulling upward f Unscrew the right battery s screws on the top and three screws on the right side of the UPS marked by a B on the top and...

Page 14: ...O Not Battery Operation 3 5 System Common Ground 6 N C 7 O Battery Voltage Low 4 8 O UPS On 5 9 O Input Power Loss Battery operation 3 Notes to Table 1 1 Pin 1 is shorted to pin 2 when any one of the...

Page 15: ...9 N C Notes to Table 2 1 Connecting 5 to 12Vdc to pin 6 to pin 1 causes the UPS to shutdown if in Battery Mode latched 2 If AC input is good pin 7 is shorted to pin 2 and pin 3 is open If AC input is...

Page 16: ...lly shorted to J3 pin 9 not used by RS232 link 8 3 Remote ON OFF Interface J5 Important note The PTC 0110BA 2 is shipped with a matting connector plugged into J5 with a jumper that enables the unit If...

Page 17: ...cy Waveform 115Vac 3 grounded neutral see Note 1 2000VA 1000W 60Hz 0 2 digitally synthesized from a crystal oscillator Sinusoidal THD 2 linear load 4 non linear BATTERY Type Capacity Charger Protectio...

Page 18: ...us lamps Input OK and Input Fail status lamps On Batt status lamp Batt Passed and Batt Failed lamps for battery self test Low Batt warning lamp Overload Shutdown status lamp Overtemp warning and Overt...

Page 19: ...vel Charge Level status of all User Programmable Options and failure diagnostic Commands UPS Shutdown UPS Standby Initiate Battery Test Enable Disable Periodic Battery Test Enable Disable Battle Mode...

Reviews: