Features cont’d.
Complete workstation protection.
Rapidly decays static charges. (1KV to 100V, < 6 sec.
@ 24”).
Excellent ion balance, 0 +10V.
Stable AC technology.
Ionization indicator light.
HV alarm (red) lights.
No periodic adjustments.
Durable, replaceable tungsten alloy emitter points.
Removable front grill.
Adjustable air volume.
Power Requirements
The Model IN5130 High Frequency AC overhead air
ionizer is powered by an internal DC switching power sup-
ply that operates from 100-240 VAC 50/60 Hz. The output
of the supply is +24 VDC @ 1.5 AMP.
Operation and Use
Environmental Conditions
The IN5130 can be operated in areas where humidity
is 20-70% RH (Non-condensing). Excess humidity may af-
fect ionizer performance. The temperature range for the
IN5130 is 65-78°F (18-25°C).
Set-up and Placement
2