Follow these instructions to clean the emitter points: 

 
1.   Remove the front grill. 
2.   

 
 
 
 
 
      Moisten a swab or wiping cloth in the IPA solution. 
3.  Swab  or  wipe  the  emitter  points  until  they  are  free  of 

particles. 

4.  Make  certain the  emitter  points are  straight and  parallel 

to the plane of the fan. 

5.  Replace the front grill.  
6.  Make sure the emitter points are dry before powering the 

ionizer again. 

 

Emitter Point Replacement 
 

 

The IN5130 uses   tungsten  alloy  precision etched  emit-

ter  needles.  Contact  Transforming  Technologies  for  infor-
mation about ordering replacement emitters. The part num-
ber for emitters is listed below: 
 

Replacement part 

 

 

Part Number 

Tungsten replacement emitters   

22-6423 

 

 

Because  the  IN5130  high  voltage  output  is  AC,  emitter 

erosion  from  the  ionization  process  on  the  electrodes  is 
minimal.  Unless  physically  broken  or  stressed,  the  IN5130 
emitters should last the life of the ionizer. 
 

Follow these instructions to remove the emitter points: 

 
1.  Turn off and disconnect the unit from the AC power. 
2.  Remove the front grill. 
3.  Unscrew the threaded emitter point using a needle nose 

pliers. 

4.  Replace and tighten the new emitter using the same 

tool. Do not over-tighten.  

5.  Repeat steps 3 and 4 as required. 

 

Summary of Contents for IN5130

Page 1: ...Static Eliminators Instruction Manual Overhead Ionizing Blower Model IN5130...

Page 2: ...ation and Use Environmental Conditions 2 Set up and Placement 2 Mounting 3 Power Connection 3 3 Maintenance Periodic Maintenance 4 Cleaning Exterior 4 Cleaning Emitter Points 4 Emitter Point Replaceme...

Page 3: ...ltage transformer makes Ptec ionizers among the most reliable products available Ptec ionizers are designed to remain in bal ance and to alarm when the HV output affects perform ance The model IN5130...

Page 4: ...rill Adjustable air volume Power Requirements The Model IN5130 High Frequency AC overhead air ionizer is powered by an internal DC switching power sup ply that operates from 100 240 VAC 50 60 Hz The o...

Page 5: ...he ceiling or other structure Power Connection Connect the IEC Cable to the main unit and plug it in an AC socket Caution Use the appropriate IEC cable for the country of use Make certain the unit is...

Page 6: ...ll Clean it with a polyes ter wiper and a cleaning solution of 50 IPA electronic grade isopropyl alcohol and 50 de ionized water As semble it when it is dry Use the same method to clean the exterior o...

Page 7: ...nologies for infor mation about ordering replacement emitters The part num ber for emitters is listed below Replacement part Part Number Tungsten replacement emitters 22 6423 Because the IN5130 high v...

Page 8: ...chnical Support for repair assistance Troubleshooting The information below provides a reference for prob lems that may arise with your IN5130 overhead blower If you have other problems not covered be...

Page 9: ...ure 66 78 F 19 25 C Humidity 20 60 RH non condensing Airflow 115 x 3 CFM typical high speed Noise level 60dB A Distance 1 meter Indicators Power green LED Alarm red LED Controls On Off rocker switch f...

Page 10: ...on or acci dent In no event shall Transforming Technologies be liable for collateral or consequential damages To receive service under warranty please con tact Transforming Technologies Technical Supp...

Page 11: ...IN5130 Line Drawing 9...