background image

 
 

Specifications 

 

 
 

 

 

 Power input 

 100-240VAC, 50/60 Hz, 36W 

 Power outlet 

 Un-fused, 0.5A or 1.0A max. 

 Ion Emission 

 AC, 68KHz 

 Balance 

 +/- 10 volts, typical offset 

 Decay Time 

 1000V - 100V < 6 seconds at 24"  

 Temperature 

 66-78°F (19-25°C) 

 Humidity 

 20-60% RH (non-condensing) 

 Airflow 

 115 x 3 CFM, typical, high speed 

 Noise level 

 60dB(A) (Distance 1 meter) 

 Indicators 

 Power: green LED    Alarm: red LED 

 Controls 

 On/Off rocker switch, fan speed knob 

 Emitter points 

 .036" dia. Tungsten alloy, etched 

 Ozone 

 <0.007 PPM  

 Mounting 

 4 "S" hooks provided 

 Dimensions 

 

2.5"H x 39.4"W x 5.75”D, (64 x 1000 x 146                

cm) 

 Weight 

 11.5lbs, (5.0kg) 

 Certifications 

 

Summary of Contents for IN5130

Page 1: ...Static Eliminators Instruction Manual Overhead Ionizing Blower Model IN5130...

Page 2: ...ation and Use Environmental Conditions 2 Set up and Placement 2 Mounting 3 Power Connection 3 3 Maintenance Periodic Maintenance 4 Cleaning Exterior 4 Cleaning Emitter Points 4 Emitter Point Replaceme...

Page 3: ...ltage transformer makes Ptec ionizers among the most reliable products available Ptec ionizers are designed to remain in bal ance and to alarm when the HV output affects perform ance The model IN5130...

Page 4: ...rill Adjustable air volume Power Requirements The Model IN5130 High Frequency AC overhead air ionizer is powered by an internal DC switching power sup ply that operates from 100 240 VAC 50 60 Hz The o...

Page 5: ...he ceiling or other structure Power Connection Connect the IEC Cable to the main unit and plug it in an AC socket Caution Use the appropriate IEC cable for the country of use Make certain the unit is...

Page 6: ...ll Clean it with a polyes ter wiper and a cleaning solution of 50 IPA electronic grade isopropyl alcohol and 50 de ionized water As semble it when it is dry Use the same method to clean the exterior o...

Page 7: ...nologies for infor mation about ordering replacement emitters The part num ber for emitters is listed below Replacement part Part Number Tungsten replacement emitters 22 6423 Because the IN5130 high v...

Page 8: ...chnical Support for repair assistance Troubleshooting The information below provides a reference for prob lems that may arise with your IN5130 overhead blower If you have other problems not covered be...

Page 9: ...ure 66 78 F 19 25 C Humidity 20 60 RH non condensing Airflow 115 x 3 CFM typical high speed Noise level 60dB A Distance 1 meter Indicators Power green LED Alarm red LED Controls On Off rocker switch f...

Page 10: ...on or acci dent In no event shall Transforming Technologies be liable for collateral or consequential damages To receive service under warranty please con tact Transforming Technologies Technical Supp...

Page 11: ...IN5130 Line Drawing 9...

Page 12: ...3719 King Rd Toledo OH 43617 P 419 841 9552 F 419 841 3241 info transforming technologies com...