roubleshooting
Failure
Possible cause
Solution
Programming cannot
be accessed
Open door
Move the shutter to any position and access to programming.
Switch off the supply for 10 seconds and program again
The door does not
open or close
Faulty connections
Check to ensure the connections are according to the diagram (Image 6)
Lack of power supply
Check the terminals 15 and 16 or 26 and 27 to detect if they have 220 V.
Unlocked engine
Lock the engine to activate the safety device. Check that the D light is on.
Blown line fuse.
Replace the 1 A fuse.
Accessories have short circuit
Disconnect all the terminals of the accessories 8 (-) and 9 (+) (there should
be a DC voltage of about 30 V) and connect them again individually.
Wrong connection of the unloc-
king device
Connect the device properly according to the diagram (Image 6(A))
The door does not
open
Verification of the sense of rotation
Press the terminals 5 and 6 with the door half opened and the door should
open.
The door does not
close
The photocell is activated or
damaged
Verify the power supply of the photocell, its connection and the existence of
obstacles. If there is no photocell, bridge the terminals 4 and 5.
Verification of the sense of rotation
Press the terminals 5 and 7 with the door half opened and the door should
close.
The door moves
slowly
The actuator has been unlocked
or the power supply has been
interrupted.
The first opening movement will be at a slow speed until the door reaches
the bumpers.
The door opens when
connected to 220 V.
Some of the accessories connected
to the terminals 3-5, 6-5 or 7-8 on
closed position.
Connect the accessory to an opened position (pusher, receiver…).
The door changes
the sense of its
movement.
Adjust the level of power
Adjust with the potentiometer. Turn the potentiometer clockwise to increase
the power and counter clockwise to reduce it.Check that that the shutter
is properly compensated by the springs. With the engine unlocked, check
manually that the door moves freely.
The door stops after
moving about 18 cm
and the sense of the
movement does not
change
Faulty Hall Sensor
Remplacer le Senseur Hall en respectant les couleurs et les bornes.* Lire
remarque annexe pour le remplacement du senseur.
Photocell and
automatic closing
features of the door
are inverted
Wrong position of the rotation #3
dip-switch
Disconnect the power supply and change the position of the #3 dip-switch.
The door does not
close smoothly or au-
tomatically
Wrong programming
Follow the programming instructions of the device for the stroke and au-
tomatic closing of the door, as described in the installation and adjustment
instructions delivered with Winner DC. Programming should be made with
the door closed.
Note: If the door does not work after verifying the above described solutions, it is advisable to replace the electronic equipment or
contact our technical department.