WARNING: THIS LUMINAIRE MUST BE USED ONLY UNDER WATER, THEREFORE CAN’T WORK OUT OF WATER
-feeding must be done through a safety power (SELV) providing 24V DC stabilized secondary tension.
The floodlight is supplied by us with the led pre-installed and connected with 3 meters cable section 2x1mm2 according CENELEC
HD 22.16.S1
(for AD8 water submersion).
The cable and the fixture must not be tampered with for any reason.
-max. installation depth 1m.
Relamping and maintenance:
-The relamping must be done with maximum attention avoiding to dirty the sealing gasket and its contact surface. It is therefore
necessary before
opening the fixture to carefully wipe the floodlight then unscrew the round frame by the proper key
-If the gasket is damaged, deformed or not in perfect conditions it is necessary to change it
-
it is essential to do a frequent cleaning of the glass and of the outer surface of the fixture to avoid build up of mud and dirtiness
resulting in dangerous
overheating due to uncorrect light and heat dissipation. Clean carefully the glass screen removing limestone deposits by means of a
scraper.
LED VERSION - RISK GROUP 2:
CAUTION: Possibly hazardous optical radiation emitted from this product. Do not stare at operating lamp. May be harmful to the
eye.The replacement must be done by a qualified electrician.
INSTALLATION:
-SWITCH-OFF THE POWER SUPPLY BEFORE CARRYING OUT ANY MAINTENANCE OPERATION
1-Unscrew the two screws of the bracket using the hexagonal key included in the package, then remove the bracket
2-choice the fixation point correspondant to the feeding point.
3–making two holes for the fixing bracket using anchors (type fischer) not included in the package, for the dimensions see the dra-
wing
4-making the appropriate electrical connection.
5-reassembling the lamp body with the bracket tighten the external screws and making the desired orientation.
Wiring for 24Vdc