4. FILTER CLEANING
The filter must be cleaned from time to time. This must be done before changing the bag collection system and
should also be done when work is completed or when there is poor suction.
Procedure:
Cover the inlet, if applicable, use attached cover. First let the machine build up vacuum for four to
five seconds then quickly push down on the key and release it. Repeat the procedure five times. It is important to
let the machine rebuild the vacuum in between every repetition.
Turn off the motor and wait until it stops completely, then uncover the inlet.
If suction remains poor, the pre-filter needs to be replaced. If suction still remains poor afterwards, the Hepa
filters needs to be replaced. See instructions in chapter 6. FILTER CHANGE.
5. DUST STORAGE SYSTEM
The dust extractors are mainly equipped with Longopac system for effective dust storage or a regular plastic bag
system depending on model. Longopac is a 22 m long plastic tube that will be divided into plastic bags using the
zip ties attached with the machine.
To assemble a new Longopac bag:
Release the belt holding the last bag. Remove the holder, put in a new
Longopac bag & pull out the inner end upwards. Assemble the holder on to the machine and strap the opening
facing upwards with the belt. Pull down the outside end and close it using a zip tie.
All dust extractors can be used with original Pullman Ermator dust bags for single use. Also all models can be
fitted with the longopac system.
Only change Longopac or regular bag after filter cleaning cycle have been completed.
6. FILTER CHANGE
Risk of dust dispersion – Use personal safety equipment
Unhealthy dust can be spread during filter change. Accordingly, the user should wear protective glasses,
protective gloves, and a breathing mask conforming to protection class FFP3.
Wear breathing mask Wear ear protection Wear protective glasses
Pre-filter
Loosen the 3 clamps and remove the top. Take the bag from the new filter.
Lift out the filter and place it gently in a plastic bag. This bag must be properly disposed.
Insert a new filter.
Important:
If you are removing the Pre-filter in order to clean it. Hitting the filter with force or use of compressed air will
destroy the filter. It can handle water, but high pressure water cleaning will destroy it.
Hepa Filter
Loosen the two nuts on each filter cover cap. Carefully lift the filter into a clean plastic bag, use the bag from the
new filter. This bag must be properly disposed. Insert a new filter in reverse order.
Important:
Hepa filters can’t be cleaned, trying this might destroy it. When installing the replacement filter, make sure to
not touch the inside of the filter. Any kind of force/damage on the inside of filter media will destroy the new
filter.
WARNING
Remember to switch off the machine and pull the plug out of the outlet before servicing.
Summary of Contents for S-Line Series
Page 11: ...S13 230V S13 120V EXPLODED VIEW...
Page 13: ...S13 230V MOTOR PACKAGE...
Page 15: ...S13 120V MOTOR PACKAGE...
Page 18: ...S26 230V S26 120V S26 230V US EXPLODED VIEW...
Page 20: ...S26 230V MOTOR PACKAGE...
Page 22: ...S26 120V MOTOR PACKAGE...
Page 24: ...S26 230V US MOTOR PACKAGE...
Page 27: ...S36 230V EXPLODED VIEW...
Page 31: ...S36 230V 30A EXPLODED VIEW...
Page 35: ...S36 230V 50A...
Page 39: ...S36 120V EXPLODED VIEW...