Revision 2
8
Function
The machine is used for sucking and separating dry, non-combustible dust with an explosion
limit value of 0.1mg/m
3
.
The motor is started by the switch. Dust laden air is then sucked through the inlet valve at high speed
via the suction hose. The air is slowed down by the cyclone and coarse dust particles are separated out,
partly by centrifugal force and partly by gravity. Air and finer particles then pass through the double
filtersystem where separation takes place. The machine is designed for filter cleaning by reverse air
pulse.
The separated dust accumulates in the cyclone until the machine is switched off, when it drops through
the bottom flap into the plastic bag.
Warning:
Before starting the machine, check that the inlet valve is in the lower position.
Use
Before use, the user must be trained in the handling of the dust extractor and the hazardous dust.
Connect the electric plug to a power outlet with the correct voltage (see the designation plate).
The filter must be cleaned from time to time. This must be done before changing the plastic bag. It can
also be done when the work is complete or when there is poor suction.
Procedure:
Cover the inlet, let the machine build up vacuum for a few seconds then quickly push
down on the top handle and release it. Repeat the procedure 4-5 times.
Turn of the motor and wait until it stops completely, then uncover the inlet.
If suction remains poor, the filter should be replaced.
The plastic bag may only be replaced after cleaning the filter.
The plastic bag must be tied up after removal.
Only use original parts.
Filter change
Risk of dust dispersion - Use of personal safety equipment
Unhealthy dust can be spread during filter change. Accordingly, the user should wear protective
glasses, protective gloves, and a breathing mask conforming to protection class FFP3.
Turn the machine off and pull the plug out of the socket.
Main filter
Loosen the two latches between the tank and the lower cyclone. Loosen the two latches at the hose
connection between the tank and the absolute filter cover. Rotate the tank forwards. Rotate the filter
plate counter clockwise 10 degrees and carefully turn filter and holder upside down. Place a plastic
bag over the filter unit. Lift the filter carefully and pinch up the bag by hand and then tie the bag up.
This bag must be properly disposed of.
Insert a new complete filter pack in reverse order. Only original filters may be used.
Absolute filter
Loosen the three latches holding the filter cover and carefully lift the filter up and into a plastic bag.
This bag must be properly disposed of. Insert new filters in reverse order.