Page 28
Operation
TM-1400 Series Progressive Scan Shutter Cameras
Model: TM-1400
Operation Mode: 15 Frames/Second
Master Clock: 100.00 MHz, M = 10 nsec
Pixel Clock: 25 MHz, P = 40 nsec
3. External Reset Timing
4. Async Shutter Reset Timing
External VD
Internal VD
FDV
Digital Data
Analog Video
VINIT Trigger
Internal VD
FDV
Digital Data
Analog Video
Horizontal Frequency: 15.55 KHz
1H = 64.32 usec
A [1053 H], (67.73 ms)
B [1 H], (64.32 us)
C [9 H], (578.88 us)
D [1044 H], (67.15 ms)
E [ 1053 H], (67.73 ms)
K [3 H], (192.96 us)
F [13 H], (836.16 us)
H [13 H], (836.16 us)
J [10 H], (643.20 us)
L [3 H], (192.96 µs)
G [1040 H], (66.89 ms)
I [1040 H], (66.89 ms)
M [1040 H], (66.89 ms)
P [1044 H], (67.15 ms)
Q [ 1053 H], (67.73 ms)
U [1040 H], (66.90 ms)
X [1040 H], (66.89 ms)
N [Variable H], (µs)
V [9 H], (578.88 us)
T [13 H], (836.16 us)
W [3 H], (192.96 µs)
O [9 H], (578.88 us)
S [13 H], (836.16 us)
R [1 H], (64.32 us)
Summary of Contents for TM-1400 Series
Page 3: ......