Mode
М
(manual)
-
Close the lens cover
,
press briefly the
ON/OFF
(
1
)
button
.
-
Open the lens cover
.
Mode SA
(semi-automatic)
-
Press briefly the
ON/OFF
(
1
)
button to calibrate
.
-
You do not need to close the lens cover (the sensor is closed with the
internal shutter automatically).
Mode А (automatic)
-
The device calibrates by itself according to the software algorithm
You do not need to close the lens cover (the sensor is closed with the
internal shutter automatically).
-
In the automatic mode the user can calibrate the sensor with the
ON/OFF
button.
135
136
10
The device allows you to quickly increase the basic magnification
(please refer to the
line in the specifications table) by two
“Digital zoom”
times or four times
8 times XP models). To operate the
(XQ models) or
(
discrete digital zoom, press successively the
button.
DOWN
(5)
The digital zoom will not be saved after the device is re-started.
QUICK MENU FUNCTIONS
11
Enter the menu with a short press of the
М (
3
)
button.
To toggle between the functions below, press successively the
M
button.
Notes.
- actual magnification is the product of the basic magnification value
and continuous digital zoom value.
For example: the device's basic magnification is 3.
, continuous
1
х
digital zoom value 1.7. Actual magnification is 5.
(3. *1.7).
х
2
х
1
- display brightness and contrast settings are saved in the memory
when the unit is turned off.
- To exit quick menu, press and hold down the
M
button or wait 5 sec
for automatic exit.
MAIN MENU FUNCTIONS
12
Select the desired mode in the menu option
“CALIBRATION”
Digital zoom
UP
/
DOWN
- press the
buttons to change digital
zoom from 1.0x to 4.0x (or 8.0x in XP models).
digital
Incremental
zoom is in 0.1x increments.
The stadiametric rangefinder
UP
/
DOWN
— press the
buttons
to
to an object being ranged (please refer to
measure distance
respective section for more details).
DISCRETE DIGITAL ZOOM
The Quick menu allows change of basic settings (display brightness and
contrast, inceremental digital zoom and stadiametric rangefinder).
Brightness
– press the
UP(2)/
DOWN
(5)
buttons to change
display brightness from 00 to 20.
Contrast
– press the
UP
/
DOWN
buttons to change display
contrast from 00 to 20.
Enter the main menu with a long press of the
М (
3
)
button.
Press the
UP(2)/
DOWN
(5)
buttons to switch between the menu
options.
Menu navigation is cyclical: as soon as the last menu option of the
first tab is reached, first menu option of the second tab starts.
Enter a menu option with a short press of the
М
button.
Exit the menu with a long press of the
М
button.
Automatic exit takes place in 10 sec of inactivity (buttons are not
pressed).
Upon exit from the menu the cursor location is memorized only for
the duration of the working session (i.e. until the unit is turned off).
Upon restarting the device and entering the menu the cursor will be
located on the first menu option.
Summary of Contents for Accolade XP38
Page 1: ...Accolade Thermal Imaging Binoculars ...
Page 2: ...1 5 2 3 4 6 6 7 7 8 11 9 13 12 10 14 15 16 Pic 1 ...
Page 18: ......