PULSAR MEASUREMENT
31
LED’s
There are two LED’s that can be seen through the lid of the
BlackBox
enclosure, which will indicate the operational status of the relays whilst in
RUN mode, as follows:
LED 1
LED 2
RUN MODE
Off
Off
Relays are in their OFF state
Constant On
Off
Relay
1
is in its ON state
Off
Constant On
Relay
2
is in its OFF state
Constant On
Constant On
Relay
1
and
2
in their
ON
state
Using the RS232 Serial Interface
The RS232 serial interface is used to program the Blackbox, and
communicate between the Blackbox and a PC using the optional BlackBox
PC and other associated Pulsar software packages, to obtain information
such as data logging and view echo traces upload, download and save
parameter files. In addition, it can also be used to control or obtain
information using a standard PC or other computer-based equipment. To do
so, the settings for control are as follows:
baud rate
19200
,
8 data bits
,
no
parity
,
1 stop bits
.
The device should be connected to the RS232 Interface via the RJ11