background image

 

 

ISFG42 

v1.0 

Industrial switch ISFG42 (2xPoE, 2xSFP)

 

 

Edition: 2 from 26.08.2020 

Supercedes the edition: 1 from 16.01.2020                

 

EN 

 

 

 

Features

 

  4 ports industrial switch  

2 PoE ports 10/100/1000 Mb/s, (1

÷2 ports)  (data and power 

supply) 
2 ports 100/1000 Mb/s SFP       

  30 W for each PoE port, supports devices complaint with the 

IEEE802.3af/at 

(PoE+)

  standard  

  Supports auto-learning and auto-aging of MAC  

addresses (8K size) 
 

 

Possibility of redundant power supply 

  Mounting on a DIN rail (TH35) 

  LED indication 

  warranty 

– 2 year from the production date 

 

          

Example of use 

 

 

 

1. Technical description

 

 

1.1. General description. 

           ISFG42 is a 4-ports PoE switch designed to supply IP cameras operating in IEEE 802.3af/at standard.  
Automatic  detection  of  any  devices  powered  in  the  PoE/PoE+  standard  is  enabled  at  the  1 

–  2  ports  of  the  switch.  

UP LINK ports (marked 3 and 4) are used to connect further network devices using fiber optics (using SFP modules  - GBIC).  
On front panel there is LEDs signaling of the device's status (description in table below). Device has solutions that allow it to be 
powered  from  two  sources  (emergency  power  supply,  redundant  power  supply) 

–  in  case  of  a  failure  of  one  source,  

it immediately switches to  backup one. 
             The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a 
separate power cable for each device. This method allows supplying other network devices, such as IP phone, wireless access 
point or router. 

 

 

Summary of Contents for ISFG42

Page 1: ...igned to supply IP cameras operating in IEEE 802 3af at standard Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 2 ports of the switch UP LINK ports marked 3 and 4 are used to connect further network devices using fiber optics using SFP modules GBIC On front panel there is LEDs signaling of the device s status description in table below Device has solutions t...

Page 2: ...1 Block diagram 1 3 Description of components and connectors Table 1 See Fig 2 Component No Fig 2 Description 1 2 x PoE ports 1 4 2 2 x UP LINK ports SFP 3 Power Socket V1 V2 4 Holder for DIN rail Fig 2 The view of the switch ...

Page 3: ...the free flow of air around the unit The PSU shall work in a vertical position that guarantees sufficient convectional air flow through ventilating holes of the enclosure The switch load balance should be done before installation Depending on application appropriate power supply should be selected PoE available only at 48 57 V 52 V recommended The given value of 30 W per port is the maximum value ...

Page 4: ...4 Connection schemes ...

Page 5: ...ion ON the device is connected 10 100Mb s Blinking data transmission OPTICAL INDICATION AT THE UP LINK PORTS GREEN LED LIGHT 3 The connection status of LAN devices and data transmission OFF the device no connection ON the device is connected Blinking data transmission GREEN LED LIGHT 4 The connection status of LAN devices and data transmission OFF the device no connection ON the device is connecte...