         Connection schemes: 

 

 
 

 

 
 

 
 

 

 
 
 
 
 
 
 
 

Summary of Contents for ISFG42

Page 1: ...igned to supply IP cameras operating in IEEE 802 3af at standard Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 2 ports of the switch UP LINK ports marked 3 and 4 are used to connect further network devices using fiber optics using SFP modules GBIC On front panel there is LEDs signaling of the device s status description in table below Device has solutions t...

Page 2: ...1 Block diagram 1 3 Description of components and connectors Table 1 See Fig 2 Component No Fig 2 Description 1 2 x PoE ports 1 4 2 2 x UP LINK ports SFP 3 Power Socket V1 V2 4 Holder for DIN rail Fig 2 The view of the switch ...

Page 3: ...the free flow of air around the unit The PSU shall work in a vertical position that guarantees sufficient convectional air flow through ventilating holes of the enclosure The switch load balance should be done before installation Depending on application appropriate power supply should be selected PoE available only at 48 57 V 52 V recommended The given value of 30 W per port is the maximum value ...

Page 4: ...4 Connection schemes ...

Page 5: ...ion ON the device is connected 10 100Mb s Blinking data transmission OPTICAL INDICATION AT THE UP LINK PORTS GREEN LED LIGHT 3 The connection status of LAN devices and data transmission OFF the device no connection ON the device is connected Blinking data transmission GREEN LED LIGHT 4 The connection status of LAN devices and data transmission OFF the device no connection ON the device is connecte...