Powering on and image setup
• Remove the lens cover
(1)
by turning it counterclockwise.
• Press the
ON
button
(9)
to turn on the thermal imager.
• Adjust the eyepiece dioptre ring of your daylight optical device until the
symbols in the display are sharp. In future, it will not be necessary to adjust
the eyepiece dioptre, regardless of the distance and other conditions.
• Rotate the lens focus knob
(10)
to focus on the visual target.
• Enter the main menu with a long press of the
MENU
button
(7)
and select the
desired calibration mode: manual
(M)
, semi-automatic
(SA)
or automatic
(A)
.
•
Calibrate the image by briefly pressing the
ON
button
(9)
. Close the lens
cover when calibrating manually.
•
Select the desired observation mode (
Forest
,
Rocks
,
Identification
or
User
)
by briefly pressing the
MODE
button
(8)
or in the main menu.
User
mode
allows you to change and save user brightness and contrast settings in the
quick menu.
•
Select one of the two color palettes by a long press of the
MODE
button
(8)
.
•
Activate the quick menu by briefly pressing the
MENU
button
(7)
to adjust the
brightness and contrast of the display (see the
Quick Menu Functions
section
of the full version manual for details).
• Upon completion of use turn the device off by a long press of the
ON
button
(9)
.
Stream Vision App
Download the Stream Vision app to stream the image (via Wi-Fi) from your
device to a smartphone or tablet, to view recorded files and update the
software on the device. A detailed user guide is available at
pulsar-vision.com
6
Summary of Contents for KRYPTON XG50
Page 1: ...Quick Start Guide KRYPTON XG50 Thermal Imaging Monocular Quick Start Guide ...
Page 11: ...ENGLISH 8 ...
Page 19: ...FRANÇAIS 16 ...
Page 27: ...DEUTSCH 24 ...
Page 35: ...ESPAÑOL 32 ...
Page 43: ...ITALIANO 40 ...
Page 51: ...РУССКИЙ 48 ...
Page 52: ...pulsar vision com ...