Note:
To
start the generator with the Economy switch in the “ON”
position
•
•
•
•
Disconnect all electrical loads from generator.
If ambient temperature is below 32ºF (0ºC) allow about 3 minutes for the engine to warm up.
The Economy is in
“ON”
position, the unit returns to normal operation after the above warm up time.
Economy switch must be turned to the “OFF” position when using elec
tronic devices that require a large starting current,
such as a compressor.
13
WARNING!
Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which
could result in injury.
•
To avoid recoil, pull starter cord slowly until resistance is felt, then pull rapidly.
OPERATION
Grounding the Generator
To avoid electrocution, this generator must be properly grounded prior to use. For instructions see Control Panel Functions
pg. 10.
Standard Atmospheric Conditions
Ambient Temperature: 77ºF (25ºC)
Barometric Pressure: 100kPa
Relative Humidity: 30%
Generator output will vary due to changes in temperature, altitude, and humidity. If the temperature, humidity, or altitude are
higher than standard atmospheric conditions, the generator’s output will be reduced. The load attached to the generator
must therefore be reduced.
How to Start Engine on Propane
•
Place generator on a level surface. All electrical loads MUST be disconnected from generator.
•
Turn the ENG. SW. to "ON”
•
Turn the fuel selector fully left to "LPG"
•
Screw the Propane hose to the Panel Propane Connection
•
DO NOT Pull the choke lever out.
•
Turn on the propane supply.
•
Press the decompression valve button for 3 to 5 seconds.
•
Pull recoil handle (starter cord) slowly until resistance is felt, then pull rap
Summary of Contents for PG2200BiS
Page 26: ...WIRING DIAGRAM G ener at or P 1 2 3 4 ...
Page 29: ...IM PG2000BiSR 22 12 2016 ...