Changing Oil

 

 

 

 

 

 

 

 

Place generator on a level surface.

 

Run the generator for several minutes until the engine is warm. Turn off generator. 
Remove screws, then remove outer casing side cover.

 

Remove the crankcase dipstick.

 

Place an oil pan underneath the engine. Tilt generator to collect used oil. Allow oil to drain completely. 
Return generator to a level surface.

 

(Crankcase Dipstick hole).

 

Use a clean rag to wipe up any spilled oil. 
Replace crankcase dipstick.

 

Reinstall outer casing side cover and tighten screws.

 

 

 

 

Recommended Engine Oil: 

SAE 10W-30

 

Recommended Engine Oil Grade: 

API Service SE type or higher quality of engine oil.

 

Engine Oil Quantity: 

0.35L (0.924 US gal)

 

2

0

0

CAUTION! 

Make sure no foreign matter enters the crankcase

 

CAUTION! 

the engine.

 

MAINTENANCE

 

Summary of Contents for PG2200BiS

Page 1: ...Inverter Gasoline OPERATOR S MANUAL support pulsar products com Warning The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm ...

Page 2: ...ctrical System 11 AddingFuel Adding Checking Oil 11 12 Operation 13 Grounding the Generator 13 How to Start Engine 13 How toStop Engine 14 Attaching Electronic Devices 14 Charging a 12 Volt Battery AC Parallel Operation Don t Overload Generator WattageReferenceGuide 15 16 17 17 Maintenance MaintenanceSchedule Checking Spark Plug Changing Oil How to Clean Air Filter 18 18 19 20 21 21 22 Checking Mu...

Page 3: ...tor is compliant with all standards set by the Environmental Protection Agency How to contact us You can contact us by Telephone 1 866 591 8921 Email support pulsar products com or write to us at PULSAR PRODUCTS INC 5721 santa Ana st Unit A Ontario California U S A 91761 Record the following information below for service or warranty assistance Date of Purchase Model Number Serial Number AC Output ...

Page 4: ...ng a generator indoors WILL KILL YOU INMINUTES Carbon monoxide gas is a poisonous odorless gas that can cause headache confusion fatigue nausea fainting sickness seizures or death If you start to experience any of these symptoms IMMEDIATELY get fresh air and seek medical attention Install a battery operated carbon monoxide alarm nearbedrooms When working in areas where vapors could be inhaled use ...

Page 5: ...rting When transporting unit disconnect the spark plug wire and make sure the fuel tank is empty with the 3 in 1 switch is turned to the off position WARNING Starter and other moving parts can catch on clothing jewelry and hair Do not wear loose clothing or gloves Remove jewelry or anything else that could be caught in movingparts Tie back or wear protective head covering to contain long hair WARN...

Page 6: ...hen operating at the preset governing speed will this generator supply the correct rated frequency and voltage WARNING Generator must be properly grounded to prevent electrocution Only operate generator on a levelsurface Always connect the nut and ground terminal on the frame to an appropriate ground source WARNING This generator produces a very high voltage which could result in burn or electrocu...

Page 7: ...tor C Muffler Cover I Control Panel J Oil Warning Light K Overload Indicator Light L AC PilotLight M Fuel Selector N Power Switch O 120V AC 15A Duplex Outlet P AC 15A Circuit Breaker 7 D Outer Casing Side Panel E Handle Grip F Air Vent G Fuel Cap H Recoil Starter FEATURES J K L M N O P Q R S T 1800W 120V AC 15A ...

Page 8: ...and power will no longer be supplied to connected electronicdevices How to Correct 1 2 Disconnect any electronic devices then stop theengine Reduce the total wattage of connected electronic devices until it is within the generator s rated output Inspect the Air Inlet and Control Panel for any blockage Remove blockage if found Restart Engine 8 Oil Warning Indicator light Overload Indicator light AC...

Page 9: ...AC Pilot Indicator light Oil Warning Indicator light Overload Indicator light AC Pilot Indicator light Engine Economy Control When the Engine Economy switch is turned to the ON position the economy control unit automatically determines the generator s proper engine speed based on the connected electronic load This results in superior fuel economy and reduces noise When the Economy switch is turned...

Page 10: ...n run Turn the Air Vent to the OFF position to stop fuel flow Ground Terminal The generator s ground terminal must always be used to connect the generator to a driven ground rod Connect the ground terminal to thedriven ground rod with a 12 AWG American Wire Gage copper wire The wire connects to the terminal between the lock washer and nut Tighten the nut securely to ensure good connection Groundin...

Page 11: ...move Do not overfill the fuel tank Provide space for fuel expansion Do not smoke when adding fuel 11 1 WARNING This generator produces a very high voltage which could result in burn or electrocution causing serious injury ordeath Never handle the generator electronic devices or any cord while standing in water while barefoot or when hands or feet are wet Always keep the generator dry Never operate...

Page 12: ...ngine oil SAE 10W 30 to empty reservoir until or oil reaches the outer edge of the oil fill hole crankcase dipstick hole Be sure to replace dipstick and securely tighten before attempting to start the engine To check oil set generator on a level surface wipe dipstick clean then reinsert dipstick without re threading Recommended Oil SAE 10W 30 Oil Capacity 0 35L 11 8oz 12 2 CAUTION generator Always...

Page 13: ...nerator must be properly grounded prior to use For instructions see Control Panel Functions pg 10 Standard Atmospheric Conditions Ambient Temperature 77ºF 25ºC Barometric Pressure 100kPa Relative Humidity 30 Generator output will vary due to changes in temperature altitude and humidity If the temperature humidity or altitude are higher than standard atmospheric conditions the generator s output wi...

Page 14: ...enerator output to stabilize engine and attached devices run evenly before plugging in the next load 14 4 WARNING Never start or stop engine with electrical devices plugged in to the receptacles Failure to do so could damage the generator and or connected electricaldevices Always start the engine and let it stabilize before connecting any electronic devices Disconnect all electronic devices before...

Page 15: ...drometer to prevent overcharging and to test the battery scondition Be careful to follow the hydrometer manufacture sinstruction 15 5 WARNING Battery electrolyte is poisonous and dangerous Do not disconnect battery clamps while charging Batteries produce explosive gasses Disconnecting the battery clamps while charging could spark andignite Do not charge battery in an enclosedarea Never smoke while...

Page 16: ...ronic device is started the red overload indicator may come on This is normal If the light stays on disconnect all electronic devices and stop the engine Indicator Light on page 8 Refer to Engine Overload 16 6 WARNING Never connect generators that are different models Only connect this generator to another PG2000BiSRGenerator Only use a PULSAR approved parallel operation cable kit to connect gener...

Page 17: ...oad within generator s powercapacity 3 Wattage Reference Guide Wattages listed are just approximations Check electronic device for actual wattage 17 7 Bathroom Rated Watts Surge Watts Hair Dryer 1250 0 Curling Iron 1500 0 Family Room X Box or Play Station 40 0 AM FM Radio 100 100 VCR 100 100 Color TV 27 500 500 Fax Machine 65 0 Personal Computer 17 Monitor 800 0 Laser Printer 950 0 Copy Machine 16...

Page 18: ...ons Service Spark Plug 12 Months 300 hr Use Clean Fuel Filter Replace if necessary Check Crankcase Breather Hose for cracks or damage Replace ifnecessary De carbonize cylinder head Seedealer Check and adjust Valve Clearance See dealer Check all Fittings and Fasteners See dealer CAUTION Only use specified PULSAR replacement parts CAUTION If you are unsure of how to perform a maintenance task have t...

Page 19: ...eplaced annually Reconnect spark plug wire Replace spark plug cap then replace cap 0 6 0 7mm Standard Spark Plug E6TC E6RTC BPR6HS Spark Plug Gap 0 6 0 7mm 0 024 0 028 in Spark Plug Torque 20 0Nm 14 8ft lb Carburetor Adjustment The carburetor is low emission and is equipped with a non adjustable idle mixture valve authorizeddealer If adjustment is needed contactan Oil Recommendations Do not use sp...

Page 20: ...lect used oil Allow oil to drain completely Return generator to a levelsurface Crankcase Dipstick hole Use a clean rag to wipe up any spilled oil Replace crankcase dipstick Reinstall outer casing side cover and tightenscrews Recommended Engine Oil SAE 10W 30 Recommended Engine Oil Grade API Service SE type or higher quality of engineoil Engine Oil Quantity 0 35L 0 924 US gal 20 0 CAUTION Make sure...

Page 21: ...p but notdripping Remove screws then remove the muffler cover asshown Check the muffler screen and spark arrester for damage If damaged replace with PULSAR replacementparts Install the outer casing and tighten the screws 21 1 WARNING Avoid contacting hot areas of this unit Allow hot components to cool before touching CAUTION Do not run the generator without reinstalling the foam element or excessi...

Page 22: ...at has collected on the generator and around the muffler and control panel Use a brush or vacuum to remove loose dirt Inspect air cooling slots Remove any debris if obstructed For short term storage start the generator once every 7days For semi long term storage add fuel stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system and carburetor For long term storage drai...

Page 23: ...tor into a gasoline approved container Wipe up any spilled fuel with a clean rag Start generator engine and let it run until it stops and all remaining fuel is consumed Do not connect electronic devices to generator during this process Remove outer casing screws then remove outercasing Turn the 3 in 1 switch to LPG position Tighten the drain screw Install the outer casing and tighten screws When t...

Page 24: ...Dirty Air filter 3 Clogged fuel filter 4 Out of fuel or Stale fuel 5 Spark plug wire disconnected from spark plug 6 Bad spark plug 7 Water in fuel 8 Overchocking 9 Low oil level 10 Engine hasflooded 11 Please try to recoil starter to starting 12 Faulty ignition 1 Make sure battery wire connection properly 2 Clean or replace Air filter 3 Clean or replace fuelfilter 4 Replace fuel 5 Reconnect spark ...

Page 25: ...cifications are subject to change without notice 25 5 Model No PG2200Bi PG2200BiS Generator Type Inverter Rated Frequency 60Hz Rated Voltage 120V Maximum Output Power 2 2kW Rated Output Power 1 8kW Power Factor 1 0 AC Output Quality ISO8528 G1 THD 3 DC Output 12V 8A Overload Protect DC Yes AC Yes Engine Engine Type Single Cylinder 4 Stroke Forced AirCooling OHV Displacement 80cc Fuel Type Unleaded...

Page 26: ...WIRING DIAGRAM G ener at or P 1 2 3 4 ...

Page 27: ...enerator components and labor Personal use means personal residential household use or recreational use by the retail consumer Commercial use means all other uses including commercial construction or other income producing purposes Once a generator has been used for commercial purposes it shall thereafter be considered as a commercial use generator for the purposes of this warranty Any portable ge...

Page 28: ... line auction websites such as ebay are not covered under this warranty Products used for commercial use are not covered under this warranty How to Obtain Warranty Service Take the original receipt and product to the place of purchase or mail the original receipt and product to the address found on the web site if purchased on line PULSAR recommends you retain all of your receipts covering the pur...

Page 29: ...IM PG2000BiSR 22 12 2016 ...

Reviews: