background image

www.pulsar.pl 

 

 

 

 

PSBS10A12E 

 

 

 

 

 
 

RED LED: 

 

on – the PSU is supplied with 230V AC  

 

off – no 230V AC supply  

 

GREEN LED: 

 

on – DC voltage in the AUX output of the PSU 

 

off – no DC voltage in the AUX output of the PSU 

- FAC; AC status indication (alarm panel, controller, indicator, LED, etc.) 
- FPS; technical output of the PSU operating status. 
- TAMPER; indication of unwanted enclosure opening or detachment from the mounting surface. 
6. With the 

I

BAT

 (J1, J2) jumpers determine the maximum battery charging current, in accordance with the battery 

parameters (see tab.1)  
7. With the P

BAT

 jumper determine if the discharged battery disconnection system U<10V (+/-5%). shall be on or off. 

The battery protection is on when the P

BAT

 jumper is removed.

  

8.  Activate the ~230V/AC supply (the AC diode and AUX, O1, O2, O3 diodes should be permanently illuminated). 
9. Check the output voltage (the PSU module voltage without load should amount to 13,6 V÷ 13,9 V, during battery 
charging  11V-13,8V).  If  the value  of  the voltage  requires  adjustment, it  should  be  set  by  the  V

ADJ

  potentiometer, 

monitoring the voltage at the AUX output of the PSU. 
10. Connect the battery in accordance with the signs: +BAT red to ‘plus’, -BAT black to ‘minus’ (the LB diode light 
should fade throughout the time of charging). 
11. Once the tests and operation control have been completed, the enclosure can be locked. 
 

3. Operating status indication. 
 

3.1 LED indication. 

The PSU is equipped with two diodes on the front panel:

 

 

 

 

 

 

Moreover, the PSU is equipped with: AC, LB, AUX, O1, O2, O3, UVP diodes. They are placed on the PCB 

of the module and indicate the PSU operation status. 

 

AC - red diode

: under normal status (AC supply) the diode is permanently illuminated. The absence of AC 

supply is indicated by the AC diode going out.  

 

LB  -  red  diode

:  indicates  the  battery  charging  process;  the  intensity  of  illumination  is  dependent  on  the 

charging current. 

 

AUX 

green  diode

:  indicates  the  DC  supply  status  at  the  output  of  the  PSU.  Under  normal  status,  the 

diode is permanently illuminated. In case of a short circuit or on overload, the diode is off.

 

 

O1, O2, O3 

– 

green diodes:

 indicate the DC power status at the AUX1, AUX2, AUX3 outputs, protected 

independently by 2,5A polyswitches. Under normal status, the diodes are permanently illuminated. In case 
of a short circuit or on overload, the diode is off.

 

 

OVP (fig.2) – red diode

: indicates activation of the over voltage protection OVP. Under normal status, the 

diode is off. If the converter’s voltage exceeds 16,5V, the diode is permanently illuminated. 

 

 

3.2 Technical outputs:  

The PSU is equipped with indication outputs. 

 

 

FAC - absence of AC supply output

: - OC type indicates the loss of AC supply. Under normal status - 

with the 230V supply, the AC output is fault to ground (status L – 0V). In case of power loss, the PSU 
output is switched into high impedance state –hi-Z after 10 sec. 

 

 

FPS - technical output of the PSU operation status

: OC type output indicating the occurrence of at least 

one of the following failures: SCP, OLP, OVP, UVP, DC/DC voltage converter’s fault. 

Under  normal  status 

(during correct operation), the output is fault to ground (status L – 0V), in case of a failure, the output is switched 
into 

high impedance state –hi-Z. 

 

 

 

TAMPER  -  output  indicating  tampering  with  the  enclosure

:

 

volt-free  (potential-free)  contacts  in  the 

output indicate the door and the PSU mounting status: PSU closed and fixed to the mounting surface: NC.  
PSU open and/or improperly mounted (e.g. torn from the wall): NO. 

 

Fig. 4. Electrical diagram of the OC outputs. 

Summary of Contents for PSBS 10A12E

Page 1: ...PSBS 10A12E v 1 0 PSBS 13 8V 10A 65Ah Buffer switched mode power supply unit EN Edition 3 from 16 09 2013 Supersedes the edition 2 from 18 09 2012 ...

Page 2: ...ration and use 4 1 Overload or short circuit of the PSU output 4 2 Battery assisted operation 4 3 Maintenance 1 Technical description 1 1 General description A buffer PSU is intended for an uninterrupted supply to alarm system devices requiring stabilized voltage of 12V DC 15 The PSU provides voltage of 13 8 V DC with current efficiency of 1 Output current 10A without a battery 2 Output current 9 ...

Page 3: ...er power supply unit PSBS 13 8V 3x5V 7 4V 12x0 5A 65Ah PSBS 10A12E 3xDCDC20 5V 7 4V 2A 3xLB4 12x0 5A AWZ574 or AWZ576 65Ah 1 2 Block diagram fig 1 Fig 1 Block diagram of the PSU 1 3 Description of PSU components and connectors tab 1 tab 2 fig 2 fig 3 Table 1 Element no Fig 2 Description 1 FBAT fuse in the battery circuit 2 START button launching the PSU from a battery 3 PBAT pin configuration of t...

Page 4: ...ack 12 FAC AC absence technical output OC type open collector hi Z level status AC power failure L level status AC supply 13 FPS technical output of the PSU operation status OC type open collector hi Z level status failure L level status correct operation 14 LED indication connector Tab 1 Element of the PSU pcb see fig 2 Fig 2 The view of the PSU pcb ...

Page 5: ...ion transformer 2 PSU board tab 1 3 TAMPER micro switch contacts of tamper resistance NC 4 FMAIN fuse in the supply circuit 230 V AC 5 L N 230 V AC power connector PE PE connector 6 Battery connectors BAT red BAT black Tab 2 PSU components see fig 3 Fig 3 The view of the PSU ...

Page 6: ...tion Over voltage protection OVP U 16 5V disconnection of the output voltage automatic return AUX disconnection Battery circuit protection SCP and reverse polarity connection 10A current limiting FBAT fuse failure requires fuse element replacement Deep discharge protection UVP U 10 0V 5 battery disconnection BAT PBAT jumper selectable Sabotage protection TAMPER output indicating enclosure opening ...

Page 7: ...urrent 9 3A 0 7A battery charge 3 Output current 7 9A 2 1A battery charge 4 Output current 6 4A 3 6A battery charge 5 Output current 5 2A 4 8A battery charge Total current of the receivers battery 10A max As the PSU is designed for a continuous operation and is not equipped with a power switch therefore an appropriate overload protection shall be guaranteed in the power supply circuit Moreover the...

Page 8: ... diode is permanently illuminated The absence of AC supply is indicated by the AC diode going out LB red diode indicates the battery charging process the intensity of illumination is dependent on the charging current AUX green diode indicates the DC supply status at the output of the PSU Under normal status the diode is permanently illuminated In case of a short circuit or on overload the diode is...

Page 9: ...the PSU power or reverse battery connection the FBAT fuse in the battery circuit becomes permanently damaged and the restoration of the voltage at the BAT output requires the replacement of the fuse 4 2 Battery assisted operation In case of the main power outage the device is immediately switched into a battery assisted operation In order to run the PSU from the battery only connect the BAT connec...

Page 10: ...that within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out at the service centre of t...