www.pulsar.pl
R812P
RACK POWER
4
Fig. 2. The front power of the power supply unit.
Fig.3. The view of the PSU.
1.4. Specifications.
- electrical parameters (tab.2)
- mechanical parameters (tab.3)
- operation safety (tab.4)
- operating parameters (tab.5)
Electrical parameters (tab. 2).
Mains supply
176÷264V AC
Current up to
0,9A@230V AC max.
Supply power
96W max.
Efficiency
83%
Output voltage
12V DC
Voltage adjustment range output
12÷15V DC
Output current
8 x 1A (
ΣΣΣΣ
I = 8A) max. @12V
Ripple
100 mV p-p max.
Short-circuit protection SCP
105% ÷ 150% of the PSU power, automatic return
Overload protection OLP
105% ÷ 150% of the PSU power, automatic return
or: 8 x PTC 1,5A
Overvoltage protection OVP
>16V (automatic recovery)
Surge protection
varistors
Optical indication of operation:
LED: AC, DC, TEMP, LoB, ALARM, AUX1÷AUX8