background image

The housing of the device can be cleaned with a soft cloth. Do not use 
an abrasive cloth/chemical cleaning solutions. 
Always  use  cleaning  equipment  designed  for  photographic 
equipment. Dust can be removed from the lens with a soft brush. The 
lens  can  be  cleaned  with  any  cloth  designed  for  cleaning  optical 
equipment. Do not pour lens cleaner on the lens itself!
Condensation on the lens may occur when bringing the device in from 
the cold. This is normal; condensation should disappear within one 
hour.

Important Note

Do  not  clean  lenses  and  unit  surfaces  with  any  paper,  such  as 
newspaper, notebook paper, etc.: this can damage the coating. 

STORAGE

Remove the unit's batteries if the device will not be used for 

long

 time

. Always 

store the 

unit

 in its case in a dry, well-ventilated area away from heating/air 

conditioning vents and other heating devices.

CLEANING

TROUBLESHOOTING

The  table  below  lists  possible  problems  that  you  may  encounter  with  your 
equipment. If the problem is not listed or the corrective actions listed do not 
correct the issue please notify the manufacturer.

Test of inspection

Corrective action 

Problem 

Monocular fails 
to activate.

Poor image.

There are several 
light or black dots 
(pixels) on the display
of the device.

Visual.
Check for defective, missing 
or improperly installed 
batteries.

Check the objective lens and 
eyepiece, making sure they are 
focused according to the 
instructions listed in section: 
OPERATING INSTRUCTIONS. 

Check for fog or dirt on the lens.

The brightness

 

adjustment wheel

(

4

)

 is in its

 

extreme position.

Presence of dots is caused 
by matrix production technology 
and is not a defect unless 
quantity exceeds 7.

Replace or install batteries.

Follow the instructions 
to adjust the device.

Adjust brightness with the wheel.

No action needed.

Peculiarities of CCD array

CCD arrays employed in Pulsar digital night vision devices, feature high quality. However certain white and 
black defective dots and variable amplitude spots are allowed. These defects can be easily detected when 
conducting observation both in the day and in the nighttime. Presence of white and black dots, spots and other 
minor defects of a CCD array (up to 4%) are acceptable in accordance with regulations of the sensor producer. 
Visibility on the screen of a white defect of equal defect level depends on the type of CCD array, camera type, 
temperature increase after the unit is switches on.

1

4

When  focusing  on  the  display  (you  can  see  the  fine  black  net)  a 
maximum of seven light or dark spots on the whole field of view in the 
image plane is acceptable. 
Design  of  the  unit  does  not  provide  for  adjustment  of  the  IR-
illuminator.

The 

built-in  l

aser  IR 

Illuminator

  complies  with  the  Class  1 

pursuant to standard IEC60825-1. This guarantees safety of the 
device.  However  avoid  looking  directly  at  the  working  laser 
diode.

 

9

8

The unit does not operate
on external power

supply.

Make sure your power supply
provides output voltage.
Make sure the central
pin of the external

power supply is intact

.

Charge the power supply
(if required).
If it's necessary, unbend 
the pin to ensure electric contact.

Summary of Contents for RECON X850

Page 1: ...RECON X850 X870...

Page 2: ...v 1115 X850 X870 X850 X870 X850 X870 X850 X870 X850 X870 X850 X870 2 9 10 17 18 25 26 33 34 41 42 49...

Page 3: ...ery is low the LED indicator 3 lights red Attention Please do not use batteries of different types or batteries with various charge level 3 2 5 5 50 mm F 1 0 300 328 5 5 9 6 5 5 5 50 mm F 1 0 350 383...

Page 4: ...15 6 The device can be powered with an external DC power supply 2 1mm pin with stabilised voltage ranging from 8 4V to 15V or a 12V vehicle socket External power supply AC DC is to be connected to po...

Page 5: ...nd jackplug AV OUT to an external device Turn on the device an image will appear on the display of an external device FUNCTION SUMLIGHT The use of Sum Light substantially increases sensitivity of the...

Page 6: ...NG INSTRUCTIONS Check for fog or dirt on the lens The brightness adjustment wheel 4 is in its extreme position Presence of dots is caused by matrix production technology and is not a defect unless qua...

Page 7: ...me d accroissement de sensibilit Grande distance d observation Haute ouverture de la lentille F d 1 0 R glage de la luminosit de l cran Haute r solution Compact l ger Sortie Vid o Alimentation ext rie...

Page 8: ...entation prise m le 2 1mm ou d un r seau d automobile La plage de la tension d entr e varie de 8 4V 15V Une source ext rieure d alimentation AC DC doit tre raccord e au port 12 Attention Dans la chevi...

Page 9: ...s affichera sur le dispositif externe FONCTION SUMLIGHT 10 ACCESSOIRES L appareil est quip avec un montage sp cial 11 qui vous permet de fixer divers accessoires tels que la torche l alimentateur ext...

Page 10: ...les ne sont pas embu es ou encrassees La molette d ajustement 4 est dans sa position extr me Pr sence de points est caus e par la technologie de la production de la matrice et n est pas d tect e tant...

Page 11: ...rhanden Eine ergonomische drehbare Augenmuschel die gegen Fremdlicht sch tzt Ihr Nachtsichtger t Recon X850 X870 eignet sich perfekt f r zahlreiche Eins tze einschlie lich Nachtbeobachtung unter nat r...

Page 12: ...er 2 1mm als auch von einem Kraftfahrzeugnetz gespeist werden Das Intervall der Eingangsspannungen liegt zwischen 8 4V und 15V Die externe Stromquelle AC DC ist an die Anschlussstelle 12 anzuschlie en...

Page 13: ...en Sie das Okular 5 bitte nicht Ihr Ger t wurde schon individuell eingestellt Um die Vergr erung des Ger tes zu steigern aktivieren Sie das digitale Zoom indem Sie die Taste Zoom 10 dr cken Der Piktog...

Page 14: ...BesonderheitenderCCD Matrizen Die CCD Chips die in den digitalen Ger ten Pulsar verwendet werden zeichnen sich durch hohe Qualit t aus Dennoch k nnen bei diesen Ger ten optische Defekte wie weisse ode...

Page 15: ...e video Alimentaci n externa Resistente a luz diurna Montura universal para montaje de accesorios Un anteojero ergon mico rotatorio que protege de la luz lateral El monocular digital de visi n nocturn...

Page 16: ...uede funcionar con una fuente externa de alimentaci n clavija 2 1mm o de la red el ctrica de autom vil La banda de tensiones de entrada es desde 8 4V hasta 15V La fuente externa de alimentaci n AC DC...

Page 17: ...i n externa EPS3 grabador de video CVR640 etc El dispositivo dispone tambi n de una rosca de sujeci n de de pulgada para montarlo sobre un tr pode ACCESORIOS PARTICULARIDADES DE EXPLOTACI N Ud puede s...

Page 18: ...efectospuedenserf cilmentedescubiertoscon laobservaci ntantoeneld acomo en la noche La presencia de puntos blancos y negros puntos y otros defectos menores de matrices CCD hasta el 4 es aceptable de a...

Page 19: ...e notturna Recon X850 X870 perfetto per una vasta gamma di usi tra cui Osservazione naturalistica Videoregistrazione e fotografia Caccia campeggio Osservazione di sport e navigazione in notturna Ricer...

Page 20: ...collega alla presa 12 del termovisore deve avere il segno L alimentatore potrebbe avere il simbolo ALIMENTAZIONE ESTERNA La connessione di un alimentatore esterno apparir il pictogramma interrompe au...

Page 21: ...endere 2 3 ore prima di usarlo con temperature calde Ci per evitare la formazione di condensa sulle lenti Non dimenticare l apparecchio al sole Non immergere in acqua Evitare di far prendere colpi al...

Page 22: ...no alcuni piccoli punti chiari o scuri pixels sul display del visore Verificare il corretto montaggio delle batterie nel contenitore Assicurarsi del corretto funzionamento delle batterie Verificare il...

Page 23: ...xAA 4 3 3 5 176x83x62 0 42 1 IEC 60825 1 2014 125 125 780 915 1 78081 78082 RECON X850 RECON X870 IP IEC60529 IPX4 IPX4 2 2 5 5 43 OLED 640x480 5 5x 2x SumLight F d 1 0 Recon X850 X870 90 Open 90 3 DC...

Page 24: ...44 5 6 7 8 9 10 11 12 1 2 3 4 ON IR S SumLight Zoom SumLight 2x x2 SumLight 15 2 1 8 4 15 3 AC DC 12 EPS3 EPS5 9 20 6 5 7 1 2 9 11 4 10 12 45 AV out...

Page 25: ...16 46 1 ON 2 3 ON 20 30 4 0 20 5 1 1 4 5 2x 10 6 IR 7 IR 7 1 3 IR x2 Video out 8 8 AV OUT 47 Sum Light 9 SumLight 2 3 11 EPS3 CVR640 10 11...

Page 26: ...IEC60825 1 14 12 13 48 Pulsar 4 49...

Reviews: