background image

 

 

S108-BR

 

v1.0 

S108-BR 10-ports switch with buffer power supply 

for 8 IP cameras and recorder

 

 

 

                                                                                                                                                 

 

        PL 

               

                               Edition: 2 from 16.04.2018 

                                                                 Supercedes the edition: 1 from 01.03.2017                                  

EN** 

 

 

Features

 

 

Uninterruptible power supply of 8 IP cameras (52V DC) 

 

Uninterruptible power supply of the recorder (12V DC)  

 

Switch 10 ports  
8 PoE ports 10/100 Mb/s, (data and power supply) 
2 ports 10/100 Mb/s (UpLink)       

 

30W for each PoE port, supports devices complaint with 
the IEEE802.3af/at 

(PoE+) 

standard  

 

Approximate backup time: 3h 15min 

 

LED indication 

 

Metal enclosure 

– color white RAL 9003 

with space for two 17Ah/12V battery 

 

Supports auto-learning and auto-aging of 
MAC addresses (1K size) 

 

warranty 

– 2 year from the production date 

 

          

Example of use. 

 

 
CONTENTS 

1. Technical description.  

1.1 General description 
1.2 Block diagram 
1.3 Description of components and connectors  
1.4 Technical parameters 

2. Installation.  

2.1 Requirements  
2.2 Installation procedure 

3. Indication of the device operation 

3.1 LED indication of operating status 
3.2 Optical indication of the switch operation 

4. Operation and use.  

4.1 Overload or short circuit of the PSU output (SCP on)  
4.2 Disconnection of discharged battery 
4.3 Maintenance 

Summary of Contents for S108-BR

Page 1: ...ime 3h 15min LED indication Metal enclosure color white RAL 9003 with space for two 17Ah 12V battery Supports auto learning and auto aging of MAC addresses 1K size warranty 2 year from the production date Example of use CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of components and connectors 1 4 Technical parameters 2 Installation 2 1 Requirements 2 2...

Page 2: ...cription of how to perform the calculations can be found at Approximate backup time assumptions for calculations Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 8 ports of the switch The UpLink ports is used for connection of another network device e g recorder The LEDs at the front panel indicate the operation status description in the table 8 The switch is ...

Page 3: ...y unit 3 DC DC50SD converter 4 DC DC52230 converter 5 Output filter 6 Tamper micro switch terminals of tamper protection NC 7 Battery space for two 2 x 17Ah 12V connect the batteries in series 8 Power supply connector of the PSU L N PE protective connector electric shock 9 BAT BAT battery output BAT red BAT black 10 DVR power cord terminated with the DC 2 1 5 5 plug ...

Page 4: ...8 ports 52V DC 30W at each port Used pairs 4 5 7 8 Protocols Standards IEEE802 3 802 3u 802 3x CSMA CD TCP IP Bandwidth 1 6Gbps Transmission method Store and Forward Optical indication of operation Switch power supply Link Act PoE Status The given value of 30W per port is the maximum value The total power consumption should not exceed 120W when all PoE ports are being used Table 4 Electrical param...

Page 5: ...ossible Connectors Power supply of the cameras RJ45 socket Power supply for recorder DC2 1 5 5 plug Outputs Φ 0 63 2 50 AWG 22 10 Battery output BAT 6 3F 2 5 TAMPER output wires Notes The enclosure does not touch the assembly surface so that cables can be led Table 6 Operation safety Protection class EN 609501 2007 I first Protection grade EN 60529 2002 U IP20 Electrical strength of insulation bet...

Page 6: ...opriate fuse in the fuse box The electrical system shall follow valid standards and regulations 2 2 Installation procedure 1 Before installation cut off the voltage in the 230V power supply circuit 2 Mount the PSU in a selected location and connect the wires 3 Connect the power cables 230V AC to L N clips of the PSU The shock protection circuit shall be performed with a particular care i e the yel...

Page 7: ...3 1 LED indication of operating status The PSU is equipped with two diodes on the front panel RED LED on the PSU is supplied with 230V AC off no 230V AC supply GREEN LED on DC voltage in the AUX output of the PSU off no DC voltage in the AUX output of the PSU ...

Page 8: ...rload YELLOW LED LIGHT LINK The connection status of LAN devices 10 100 Mb s and data transmission OFF no connection ON the device is connected 10 100Mb s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORTS GREEN LED LIGHT Applies only to the right side port No light OFF No supply voltage of the switch ON the switch is powered correct operation YELLOW LED LIGHT LINK The connection st...

Page 9: ...arged battery disconnection system During the battery assisted operation reducing voltage below 19V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network The PSU does not require performing any specific maintenance measures however in case of significant dust...

Page 10: ...ipment should be disposed of separately from normal household waste The power supply unit is adapted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycled according to the applicable law Pulsar Siedlec 150 32 744 Łapczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar pl http www pulsar pl www zasilacze pl ...