background image

 

 
1. Technical description

 

 

1.1. General description. 

The S108-BR is dedicated for uninterruptible power supply of 8 IP cameras (52V DC power supply) and uninterruptible 

power supply of the DVR (12V DC power supply). 

 
The main elements of this system include: 
- 10 ports PoE switch  
- buffer power supply unit 27,6V (PSB-30024100) which can accommodate two x 17Ah / 12V batteries  
- a converter (DC/DC52230) increasing the voltage to 52V DC (supply of the PoE switch) 
- a converter (DC/DC50SD) buck to 12V DC (DVR power supply) 
 
In case of power decay, a battery back-up is activated immediately. 
 

             The  approximate  backup  time  is  given  assuming  that  all  output  ports  are  used  (using  typical  devices  and  17Ah 
batteries).  The  electricity  consumption  for  own  needs  and  the  energy  efficiency  of  the  power  intake  track  were  taken  into 
account. The exact description of how to perform the calculations can be found at: 

"Approximate backup time - assumptions for 

calculations"

. 

 
Automatic detection of any devices powered in the PoE/PoE+ standard is enabled at the 1 - 8 ports of the switch. 

The  UpLink  ports  is  used  for  connection  of  another  network  device  e.g.  recorder.  The  LEDs  at  the  front  panel  indicate  the 
operation status (description in the table. 8). 

 
The switch is housed in a metal enclosure (color RAL 9003) which can accommodate  a two  17Ah/12V batteries. The 

enclosure features a micro switch tamper indicating door opening (front panel). The S108-BR is fitted with two LEDs on the 
front panel (red LED 

– indicates 230V AC power supply of the PSU, green LED indicates the presence of DC voltage). 

 
The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a 

separate  power  cable  for  each  device.  This  method  allows  supplying  other  network  devices,  such  as  IP  phone,  wireless 
access point or router. 

 

1.2  Block diagram. 

 

 

 

Fig. 1. Block diagram. 

 
 
 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for S108-BR

Page 1: ...ime 3h 15min LED indication Metal enclosure color white RAL 9003 with space for two 17Ah 12V battery Supports auto learning and auto aging of MAC addresses 1K size warranty 2 year from the production date Example of use CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of components and connectors 1 4 Technical parameters 2 Installation 2 1 Requirements 2 2...

Page 2: ...cription of how to perform the calculations can be found at Approximate backup time assumptions for calculations Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 8 ports of the switch The UpLink ports is used for connection of another network device e g recorder The LEDs at the front panel indicate the operation status description in the table 8 The switch is ...

Page 3: ...y unit 3 DC DC50SD converter 4 DC DC52230 converter 5 Output filter 6 Tamper micro switch terminals of tamper protection NC 7 Battery space for two 2 x 17Ah 12V connect the batteries in series 8 Power supply connector of the PSU L N PE protective connector electric shock 9 BAT BAT battery output BAT red BAT black 10 DVR power cord terminated with the DC 2 1 5 5 plug ...

Page 4: ...8 ports 52V DC 30W at each port Used pairs 4 5 7 8 Protocols Standards IEEE802 3 802 3u 802 3x CSMA CD TCP IP Bandwidth 1 6Gbps Transmission method Store and Forward Optical indication of operation Switch power supply Link Act PoE Status The given value of 30W per port is the maximum value The total power consumption should not exceed 120W when all PoE ports are being used Table 4 Electrical param...

Page 5: ...ossible Connectors Power supply of the cameras RJ45 socket Power supply for recorder DC2 1 5 5 plug Outputs Φ 0 63 2 50 AWG 22 10 Battery output BAT 6 3F 2 5 TAMPER output wires Notes The enclosure does not touch the assembly surface so that cables can be led Table 6 Operation safety Protection class EN 609501 2007 I first Protection grade EN 60529 2002 U IP20 Electrical strength of insulation bet...

Page 6: ...opriate fuse in the fuse box The electrical system shall follow valid standards and regulations 2 2 Installation procedure 1 Before installation cut off the voltage in the 230V power supply circuit 2 Mount the PSU in a selected location and connect the wires 3 Connect the power cables 230V AC to L N clips of the PSU The shock protection circuit shall be performed with a particular care i e the yel...

Page 7: ...3 1 LED indication of operating status The PSU is equipped with two diodes on the front panel RED LED on the PSU is supplied with 230V AC off no 230V AC supply GREEN LED on DC voltage in the AUX output of the PSU off no DC voltage in the AUX output of the PSU ...

Page 8: ...rload YELLOW LED LIGHT LINK The connection status of LAN devices 10 100 Mb s and data transmission OFF no connection ON the device is connected 10 100Mb s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORTS GREEN LED LIGHT Applies only to the right side port No light OFF No supply voltage of the switch ON the switch is powered correct operation YELLOW LED LIGHT LINK The connection st...

Page 9: ...arged battery disconnection system During the battery assisted operation reducing voltage below 19V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network The PSU does not require performing any specific maintenance measures however in case of significant dust...

Page 10: ...ipment should be disposed of separately from normal household waste The power supply unit is adapted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycled according to the applicable law Pulsar Siedlec 150 32 744 Łapczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar pl http www pulsar pl www zasilacze pl ...

Reviews: