5
Short-circuit protection SCP and overload protection OLP
105% ÷ 150% of power supply, manual restart
(the fault requires disconnection of the DC output circuit)
PSU current consumption
300mA/27,6V
Battery charge current
1,0A max. /2x17Ah (+/-5%)
Approximate backup time
3h 15min
Battery circuit protection SCP and reverse
polarity connection
melting fuse
Deep discharge battery protection UVP
U<19V (± 5%) – disconnection of the batteries
Sabotage protection:
- TAMPER output indicating enclosure opening
- microswitch, NC contacts (enclosure closed),
0,5A@50V DC (max.)
Table 5. Mechanical parameters
Dimensions
W=397, H=350, D+D
1
=92+8 [+/- 2mm]
W
1
=402, H
1
=355 [+/- 2mm]
The dimensions of the
battery compartment
370 x 180 x 80mm (WxHxD) max
Gross/Net weight
5,5 / 5,8 kg
Enclosure
Steel plate, DC01 1,0mm color white RAL 9003
Closing
Cheese head screw x 2 (at the front), (lock assembly possible)
Connectors
Power supply of the cameras: RJ45 socket
Power supply for recorder: DC2,1/5,5 plug
Outputs:
Φ 0,63-2,50 (AWG 22-10),
Battery output BAT: 6,3F-2,5
TAMPER output: wires
Notes
The enclosure does not touch the assembly surface so that cables can be led.
Table 6. Operation safety
Protection class EN 609501:2007
I (first)
Protection grade EN 60529: 2002 (U)
IP20
Electrical strength of insulation:
- between input and output circuits of the PSU (I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100 MΩ, 500V/DC
Declarations
CE
Table 7. Operating parameters
Operating temperature
-
10ºC...+40ºC
Storage temperature
-
20ºC...+60ºC
Relative humidity
20%...90%, without condensation
Vibrations during operation
unacceptable
Impulse waves during operation
unacceptable
Direct insulation
unacceptable
Vibrations and impulse waves during transport
According to PN-83/T-42106