3. Optical indication of the switch operation (see Table 4). 

 

Table 4. Indication of the switch operation 

 

OPTICAL INDICATION AT THE PoE PORTS (1

÷8) 

GREEN LED LIGHT (PoE) 
Indication of the PoE power 
supply at the RJ45 ports 
 

 

 

OFF

- no power supply at the RJ45 port (the device is not connected  

         or not compliant with the IEEE802.3af/at  standard) 

ON

 

– supply at the RJ45 port 

Blinking

 

– short-circuit or output overload 

YELLOW LED LIGHT (LINK) 
The connection status of LAN 
devices, 10/100Mb/s 
and data transmission 

 

 

OFF

- no connection 

ON 

- the device is connected; 10/100Mb/s 

Blinking

 

– data transmission 

 

OPTICAL INDICATION AT THE UP LINK PORT 

GREEN LED LIGHT 

 

 

Applies only to the right side port: 
No light 

(OFF)

 - No supply voltage of the switch 

ON

 -  the switch is powered, correct operation 

YELLOW LED LIGHT (LINK) 
The connection status of LAN 
devices, 10/100Mb/s 
and data transmission 

 

 

OFF

- no data transmission 

ON 

- the device is connected: 10/100Mb/s 

Blinking

 

– data transmission 

 

 

 

WEEE LABEL 

 

Waste electrical and electronic equipment must not be disposed of with normal household waste. 

According to the European Union WEEE Directive, waste electrical and electronic equipment 

should be disposed of separately from normal household waste. 

 

 

 

 
 

 

 
 
 

 

Pulsar  

Siedlec 150,  32-744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail

biuro@pulsar.pl

sales@pulsar.pl

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

Summary of Contents for S108-CR

Page 1: ... warranty 2 year from the production date Example of use 1 Technical description 1 1 General description The S108 CR is a complete kit to build the CCTV system based on IP cameras The switch is placed in a metal enclosure with recorder space Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 8 ports of the switch The UP LINK ports is used for connection of anoth...

Page 2: ...meter adjusting the output voltage of the power supply 48 53V 4 LED light power supply operation indication 5 T 6 3A 250V fuse socket 6 Mounting brackets for cables 7 Space for the power supply of the recorder desktop type of dimensions max 180x40x100 mm 8 Power Socket of the 230V AC recorder 9 Recorder space of dimensions max 400x345x95mm WxHxD 10 Straps for attaching the DVR in enclosure Fig 2 T...

Page 3: ...ach port Used pairs 4 5 7 8 Protocols Standards IEEE802 3 802 3u 802 3x CSMA CD TCP IP Bandwidth 1 6Gbps Output current at the PoE ports RJ45 8 x 0 6A ΣI 2 3A max Transmission method Store and Forward Optical indication of operation Switch power supply Link Act PoE Status Mains supply 176 264VAC 50Hz 1 1A 230VAC Operating conditions Temperature 10 C 40 C relative humidity 5 90 no condensation Dime...

Page 4: ...ct the operation of the switch The device is designed for a continuous operation and is not equipped with a power switch Therefore an appropriate overload protection in the power supply circuit should be provided Moreover the user should be informed how to disconnect the power supply unit from the mains supply usually by assigning an appropriate fuse in the fuse box The electrical system shall be ...

Page 5: ...n OPTICAL INDICATION AT THE UP LINK PORT GREEN LED LIGHT Applies only to the right side port No light OFF No supply voltage of the switch ON the switch is powered correct operation YELLOW LED LIGHT LINK The connection status of LAN devices 10 100Mb s and data transmission OFF no data transmission ON the device is connected 10 100Mb s Blinking data transmission WEEE LABEL Waste electrical and elect...