S64 6-port switch for 4 IP cameras 

 

 
 

                                                                                                                                                 

 

        PL 

               

 Edition: 1 from 20.12.2017 

Supercedes the edition: ----------- 

EN** 

 

 

Features: 

 

 

Switch 6 ports 
4 PoE ports

 10/100Mb/s (data transfer and power 

supply)  
2 ports 10/100Mb/s (UP LINK) 

 

30W for each PoE port, supports devices complaint 
with the IEEE802.

3af/at standard 

 

Supports auto-learning and auto-aging of MAC 
addresses (1K size) 

 

LED indication 

  The PSD 520115 52VDC/1,15A/60W max. 

power supply desktop type included 

  Additional assembly elements 

  warranty 

– 2 year from the production date  

 

Example of use.

 

 

                                            

1.  Technical description

  

 

1.1. General description. 

            

S64 is a 6-ports PoE switch designed to supply IP cameras operating in IEEE 802.3af/at standard. Automatic detection 

of  any  devices  powered  in  the  PoE  standard  is  enabled  at  the  1 

–  4  ports  of  the  switch.  The  UP  LINK  ports  is  used  for 

connection of another network device via RJ45 connector. The LEDs at the front panel indicate the operation status (description 
in the table below). 
               The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a 
separate power cable for each device. This method allows supplying other network devices, such as IP phone, wireless access 
point or router. 
 
 
 
 
 
 

Summary of Contents for S64

Page 1: ...ion date Example of use 1 Technical description 1 1 General description S64 is a 6 ports PoE switch designed to supply IP cameras operating in IEEE 802 3af at standard Automatic detection of any devices powered in the PoE standard is enabled at the 1 4 ports of the switch The UP LINK ports is used for connection of another network device via RJ45 connector The LEDs at the front panel indicate the ...

Page 2: ...1 Block diagram 1 3 Description of components and connectors Table 1 see Fig 2 Element no Fig 2 Description 1 2 x UP LINK port 2 4 x PoE port 1 4 3 Power Socket of the DC 4 Additional mounting elements Fig 2 The view switch a ...

Page 3: ...ive humidity RH 90 maximum without condensation and temperature from 10 C to 40 C Ensure the free flow of air around the unit The PSU shall work in a vertical position that guarantees sufficient convectional air flow through ventilating holes of the enclosure The load balance should be done before installation Switcha The given value of 30W per port is the maximum value referring to a single outpu...

Page 4: ...4 Connection schemes ...

Page 5: ... no connection ON the device is connected 10Mb s or 100Mb s Blinking data transmission OPTICAL INDICATION AT THE UP LINK PORTS GREEN LED LIGHT OFF no connection the device is connected 10Mb s ON the device is connected 100Mb s YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no data transmission ON the device is connected 10Mb s or 100Mb s Blin...

Reviews: