background image

1.4. Technical parameters (table 2.) 

 

 

 

       

Table 2. 

            

Ports 

10 ports 10/100/1000Mb/s (8 x PoE + 2 x UP LINK) 

 with connection speed auto-negotiation and MDI/MDIX Auto Cross 

PoE power supply 

IEEE 802.3af/at (1

÷8 ports),  52 V DC / 30 W at each port *   

Protocols, Standards 

IEEE802.3, 802.3u, 802.3x  CSMA/CD, TCP/IP 

Bandwidth 

16 Gbps 

Transmission method 

Store-and-Forward 

Optical indication of 
operation 

Switch power supply  

Link 

SPD 

PoE Status 

Power supply 

~100-240 V; 50/60 Hz; 1,5 A  

the PSD 520230 52V DC/2,3 A/120 W max. power supply desktop type 

Operating conditions 

temperature -10 

°C ÷ 40 °C,  

relative humidity  5 % - 90 %, no condensation 

Dimensions  

W=190, H=27, D=105 [+/- 2 mm] 

Additional equipment 

plate to be fixed surface 

Net/gross weight 

1,2/1,4 kg 

  

Protection class        
EN 60950-1:2007 

II (second) 

Storage temperature 

-20 

°C ÷ 60 °C 

Declarations 

CE 

*

 

The given value of 30 W per port is the maximum value. The total power consumption should not exceed 96 W.  

 

 2.

 

Installation. 

 

2.1. Requirements. 

         The  unit  should  be  mounted  in  confined  spaces,  in  accordance  with  the  2nd  environmental  class,  with  normal 
relative  humidity  (RH=90  %  maximum,  without  condensation)  and  temperature  from  -10 

°C  to  +40  °C.  Ensure  the  free 

flow  of  air  around  the  unit.  The  PSU  shall  work  in  a  vertical  position  that  guarantees  sufficient  convectional  air-flow 
through ventilating holes of the enclosure.  
          The switch load balance should be done before installation. The given value of 30 W per port is the maximum value 
referring to a single output. The total power consumption should  not  exceed  96  W. The increased  demand for power is 
particularly  evident  in  the  case  of  cameras  with  heaters  or  infrared  illuminators  -  when  launching  these  features,  the 
power consumption increases rapidly, which may adversely affect the operation of the switch. As the device is designed for 
a  continuous  operation  and  is  not  equipped  with  a  power-switch,  therefore    an  appropriate  overload  protection  in  the  power 
supply circuit should be provided. The electrical system shall be made in accordance with applicable standards and regulations. 

 

     2.2.  Installation procedure. 

1. Connect switch to the PSD520230 52 V DC power supply unit desktop type.    

 

2. Connect the power supply to the 230 V socket. 
3. Connect the camera wires to the RJ45 connectors (connectors PoE). 
4. Check the optical indication of switch operation (see Table 3). 
 

 

 
 

           

Summary of Contents for SG108

Page 1: ...m the production date Example of use 1 Technical description 1 1 General description SG108 is a 10 ports PoE switch designed to supply IP cameras operating in IEEE 802 3af at standard Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 8 ports of the switch The UP LINK ports is used for connection of another network device via RJ45 connector The LEDs at the front...

Page 2: ...1 Block diagram 1 3 Description of components and connectors Table 1 see Fig 2 Element no Fig 2 Description 1 8 x PoE port 1 8 2 2 x UP LINK port 3 Power Socket of the DC 4 Additional assembly elements Fig 2 The view switch a ...

Page 3: ...ve humidity RH 90 maximum without condensation and temperature from 10 C to 40 C Ensure the free flow of air around the unit The PSU shall work in a vertical position that guarantees sufficient convectional air flow through ventilating holes of the enclosure The switch load balance should be done before installation The given value of 30 W per port is the maximum value referring to a single output...

Page 4: ...4 Connection schemes ...

Page 5: ... no connection ON the device is connected 10 100 1000 Mb s Blinking data transmission OPTICAL INDICATION AT THE UP LINK PORTS GREEN LED LIGHT OFF no connection the device is connected 10 Mb s or 100 Mb s ON the device is connected 1000 Mb s YELLOW LED LIGHT LINK The connection status of LAN devices 10 100 1000 Mb s and data transmission OFF no data transmission ON the device is connected 10 100 10...

Reviews: