2.2 Installation procedure.

  

 

 

CAUTION! 

Before installation, cut off voltage in 230 V power-supply circuit. To switch power off, use an 
external switch, in which distance between contacts of all poles in disconnection state is not 
less than 3mm. 
 

         It  is required  to  install  an  installation  switch with  a  nominal current  of  min.  3  A  in  the  power  supply 
circuits outside the power supply unit. 

 

1.  Mount the device  in a selected location and connect the wires.  
2.  Remove mounting plate by unscrewing screws, then release plate from hooks (slide up and slightly pull). 
3.  Connect the power cables (~230 V) to L-N clips of the PSU. Connect the ground wire to the clip marked by the 

earth symbol 

. Use a three-core cable (with a yellow and green 

 protection wire) to make the connection. 

Lead the cables to the appropriate clips through the insulating bushing of the PSU..

 

 

 

 

Shock protection circuit shall be done with a particular care: yellow and green wire coat 

of  power  cable  should  be  connected  to  terminal  marked  with  the  grounding  symbol  on  PSU 
enclosure. Operation of PSU without the properly made and fully operational shock protection 
circuit is UNACCEPTABLE! It can cause damage to equipment or an electric shock. 

  

 

4.  Connect battery in correct polarity. 
5.  Make the selection is done with use of the I

BAT

 jumpers (see: tab.1) 

6.  Screw switch to mounting plate.  
7.  Connect switch using cable terminated with a DC 2.1/5.5 plug. 
8.  Mount inside enclosure. 
9.  Connect the power 230 V 

 

10.  After installing and checking proper working, the enclosure can be closed.  

 

3.  

Maintenance. 

Any and all maintenance operations may be performed following the disconnection of the PSU module from the 

power supply network. The PSU does not require performing any specific maintenance measures, however, in the case 
of significant dust rate, its interior is recommended to be cleaned with compressed air. In the case of a fuse replacement, 
use a replacement of the same parameters.  

 

 

 

 
 

WEEE LABEL 

 

Waste electrical and electronic equipment must not be disposed of with normal household waste. 

According to the European Union WEEE Directive, waste electrical and electronic equipment 

should be disposed of separately from normal household waste. 

 

 

CAUTION!

 

The power supply unit is adapted for cooperation with the sealed lead-acid batteries (SLA). After the operation period they must 

not be thrown but recycled according to the applicable law. 

 

 
 
 
 
 
 
 

Pulsar sp. j.  

Siedlec 150, 32-744 Łapczyca, Poland 

Tel.  (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

E-mail: 

biuro@pulsar.pl

sales@pulsar.pl

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

Summary of Contents for SWB-60

Page 1: ...USER MANUAL EN Edition 1 from 24 09 2020 Supersedes the edition SWB 60 Buffer power supply system for PoE switches 52VDC 7Ah 60W ...

Page 2: ...n procedure 3 Maintenance 1 Technical description 1 1 General description Buffer power supply system for PoE switches SWB 60 is designed for uninterrupted power supply of PoE switches with 52 V DC It was designed based on high energy efficiency switching power supply module placed in metal enclosure color RAL 9003 DC DC converter used to increase voltage allows to reduce costs of system by limitin...

Page 3: ...e 4 Cable bushing 5 TAMPER microswitch of antisabotage protection NC 6 Switch power cable terminated with a DC 2 1 5 5 plug 7 BAT BAT battery output BAT red BAT black 8 Selection jumper for charging current Ibat 1 0 A Ibat 2 0 A Description jumper installed jumper removed Fig 3 View of PSU 1 4 Specifications electrical parameters tab 3 mechanical parameters tab 4 operation safety tab 5 operating p...

Page 4: ...tion class EN 62368 1 I first Degree of Protection EN 60529 IP20 Electrical strength of insulation between input input and output circuits of the PSU between input circuit and protection circuit between output circuit and protection circuit 2500 V AC min 1500 V AC min 500 V AC min Insulation resistance between input circuit and output or protection circuit 100 MΩ 500 V DC Table 4 Operating paramet...

Page 5: ...age to equipment or an electric shock 4 Connect battery in correct polarity 5 Make the selection is done with use of the IBAT jumpers see tab 1 6 Screw switch to mounting plate 7 Connect switch using cable terminated with a DC 2 1 5 5 plug 8 Mount inside enclosure 9 Connect the power 230 V 10 After installing and checking proper working the enclosure can be closed 3 Maintenance Any and all mainten...

Reviews: