Product Specification
PHYSICAL
Fascia Mount dimensions
200 x 112 x 108mm
Weight
1.3kg
Enclosure material/description
Stainless steel back, ABS front and bezel
Transducer Cable Extensions
2-core screened
Maximum Separation
1000m (3,280 ft), 500m (1,640 ft) for mmWave
ENVIRONMENTAL
IP Rating
IP64
Max. & min. temperature
(electronics)
-20 ºC to +50 ºC
Flammable atmosphere approval
Safe area: compatible with approved dB transducers
(see transducer spec' sheet)
CE Approval
See EU Declaration of Conformity
PERFORMANCE
Accuracy
0.25%
of the measured range or 6 mm (whichever is
greater). mmWAVE ± 2mm.
Resolution
0.1%
of the measured range or 2 mm (whichever is
greater)
Max. Range
Dependant on transducer (maximum 40m dB40)
Min. Range
Dependent upon application and transducer
(minimum zero dB Mach3)
Rate Response
Fully adjustable
ECHO PROCESSING
Description
DATEM (Digital Adaptive Tracking of Echo Movement)
OUTPUTS
Analogue I/O
Isolated (floating) output (to 150V) of 4-20 mA or 0-20
mA into 500
(user programmable and adjustable)
0.1%
resolution
Digital output
Full Duplex RS232
Volt free contacts, number, and
rating
6 form "C" (SPDT) rated at 5A at 240V AC
Display
6 digits plus 12-character text, plus bar graph with
direction indicators, remote communicator identifier,
and program/run/test mode indicators