background image

PSA3000 Hardware Guide

 

© 2018 Pulse Secure, LLC. All rights reserved

 

33

 

 

 

 

Warnung

 

 

Diese  Einheit  ist  zur  Installation  in  Bereichen  mit  beschränktem  Zutritt  vorgesehen.  Der  Zutritt  zu 
derartigen  Bereichen  ist  nur  mit  einem  Spezialwerkzeug,  Schloss  und  Schlüssel  oder  einer  sonstigen 
Sicherheitsvorkehrung möglich.

 

 
 

 

¡Advertencia!

 

 

Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso 
a una de estas áreas mediante la utilización de una herramienta especial, cerradura con llave u otro medio 
de seguridad.

 

 
 

 

Attention

 

 

Cet  appareil  doit  être  installée  dans  des  zones  d'accès  réservés.  L'accès  à  une  zone  d'accès  réservé  n'est 
possible qu'en utilisant un outil spécial, un mécanisme de verrouillage et une clé, ou tout autre moyen de 
sécurité.

 

 

תלבגומ

 

השיג

 

םע

 

רוזא

 

 

 !

הרהזא

תרזעב

 

תנתינ

 

השיגה

השיג

 

תלבגה

 

םהב

 

שיש

 

םירוזאב

 

הדיחיה

 

תא

 

ןיקתהל

 

שי

 

.)

דכו

 

לוענמ

 ,

חתפמ

דבלב

 

החטבא

 

ילכ

'

 

 
 

 

 

ةروظحم قطانم   ف اهبُكرتن ةذحىنا هذه صيصخت مت .

 

ٌ تصاخ ةادأ واذختسا للاخ نم طقف ةروظحم تقطنم   نإ لىصىنا نكم،

 

املأملان يرخأ تهُسو   أ وأ 

 

حاتفمو مفق

 

 
 

 

경고

!

 

 

 

장치는

 

접근이

 

제한된

 

구역에

 

설치하도록

 

되어있습니다

특수도구

잠금

 

장치

 

 

또는

 

기타

 

보안

 

수단을

 

통해서만

 

접근

 

제한

 

구역에

 

들어갈

 

 

있습니다

.

 

 

Waarschuwing

 

 

Dit  apparaat  is  bedoeld  voor  installatie  in  gebieden  met  een  beperkte  toegang.  Toegang  tot  dergelijke 
gebieden kunnen alleen verkregen worden door gebruik te maken van speciaal gereedschap, slot en sleutel 
of andere veiligheidsmaatregelen.

 

Summary of Contents for PSA3000

Page 1: ...PSA3000 Hardware Guide Pu ub blish he ed Da at te February 2018 Document Revision 1 1...

Page 2: ...ut notice Pulse Secure LLC assumes no responsibility for any inaccuracies in this document Pulse Secure LLC reserves the right to change modify transfer or otherwise revise this publication without no...

Page 3: ...11 Component Specifications 12 Regulatory Certifications 12 Mounting in a Rack 12 Where to Get Replacement Components 12 Console and Initial Configuration 13 Connect Console and Network 13 Power On th...

Page 4: ...tions 27 Circuit Breaker 28 Power Disconnection Warning 29 Equipment Installation 31 Restricted Area 32 Redundant Power Supplies 34 Backplane Voltage 35 Comply with Local and National Electrical Codes...

Page 5: ...ncy 80 low noise 200W power supply High performance fans provide ample optimized cooling Power switch Console Remote management Internal port INT External port EXT Note For added system security the U...

Page 6: ...dby power supplied to the system Therefore you must unplug system before servicing Reset The reset button is used to reboot the system Control Panel LEDs The control panel displays six LEDs to monitor...

Page 7: ...vity when flashing NIC2 GLAN2 Unused Will always be off HDD Indicates IDE channel activity or SATA drive activity when flashing Power Indicates power is being supplied to the system power supply This...

Page 8: ...indicate the speed of the connection LED Color Description Activity Yellow flashing Active Link Off No connection Amber 1 Gbps speed Green 100 Mbps speed INT and EXT Port LEDs Two LAN ports are locate...

Page 9: ...Pulse Secure LLC All rights reserved 9 Beeping and Alarms Beep Code Description 5 short beeps 1 long beep every 5 seconds No memory detected in the system Continuous beep i LED on front panel turns RE...

Page 10: ...figures are for an unpackaged system Category Description Form factor 1U chassis Width 17 2 inches 43 7 cm Height 1 7 inches 4 3 cm Depth 9 8 inches 24 9 cm Weight 10 lbs 4 5 kg Power Rating Below is...

Page 11: ...A Server with Motherboard Fan and Storage Drive Total Power 46 5 46 5 Total Current 3 0 1 9 0 1 1x Power Supply 100 240Vac Rating 200 16 8 8 2 0 5 120 Vac input 240 Vac input Actual output wattage fro...

Page 12: ...100 1000 management port Cooling 1x fan with tachometer status monitoring Regulatory Certifications USA UL listed FCC Canada CUL listed Germany TUV Certified Europe CE Mark EN 60950 IEC 60950 Complian...

Page 13: ...nnect the RJ45 end of the cable to the appliance port labeled CONSOLE and the DB9 end to a laptop Additionally connect a network cable from the INT port on the appliance to a switch port 3 On the lapt...

Page 14: ...ng the first 60 seconds Configure Basic Settings When you boot an unconfigured PSA3000 you need to enter basic network and machine information through the console to make it accessible to the network...

Page 15: ...onsole after initial configuration Network mask Default gateway address Primary DNS server address Secondary DNS server address optional Default DNS domain name for example acmegizmo com WINS server n...

Page 16: ...Operations 3 Select option 5 Factory reset 4 Enter the number corresponding to the personality for which you want to configure the PSA3000 For example if your screen looks like this Please select a fa...

Page 17: ...in page enter the administrator username and password you created earlier Then click Sign In The administrator Web console opens to the Overview page Licensing the System After you install the device...

Page 18: ...nstall in a restricted access location such as a dedicated equipment room or service closet Ambient Operating Temperature If installed in a closed or multi unit rack assembly the ambient operating tem...

Page 19: ...the rack to become unstable Warning Follow these guidelines to prevent injury Take all precautions to ensure the system remains stable General Server Precautions Review the electrical and general safe...

Page 20: ...only Servers should always be installed in racks from the bottom up Installing the Chassis into a Standard Rack Installing the Chassis in a Standard Rack 1 Confirm that chassis includes the four mount...

Page 21: ...rical safety precautions should be followed to protect yourself from harm and the system from damage Be aware of the locations of the power on off switch on the system as well as the room s emergency...

Page 22: ...en specifically designed as electrical insulators The power supply power cord must include a grounding plug and must be plugged into grounded electrical outlets Use a grounded wrist strap designed to...

Page 23: ...rved 24 Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and b...

Page 24: ...quier equipo considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar...

Page 25: ...chamelijk letsel kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de...

Page 26: ...or dem Anschlie en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Av...

Page 27: ...A 250 V 20 A 250V 20A 250V 20A Warnung Dieses Produkt ist darauf angewiesen dass im Geb ude ein Kurzschluss bzw berstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtu...

Page 28: ...er Disconnection Warning Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chassis interior to install or...

Page 29: ...itar componentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour install...

Page 30: ...d and qualified personnel should be allowed to install replace or service this equipment Warnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal...

Page 31: ...eerd vervangen of hersteld door geschoold en gekwalificeerd personeel Restricted Area Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed...

Page 32: ...enerse acceso a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r s...

Page 33: ...m sicherzustellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para corta...

Page 34: ...g Warnung Wenn das System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el voltaje...

Page 35: ...ebruik is Voorzichtigheid is geboden tijdens het onderhoud Comply with Local and National Electrical Codes Warning Installation of the equipment must comply with local and national electrical codes Wa...

Page 36: ...stall conform ment aux normes lectriques nationales et locales Waarschuwing Product Disposal Warning Ultimate disposal of this product should be handled according to all national laws and regulations...

Page 37: ...mis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Waarschuwing De uiteindelijke verwijdering van dit product dient te ges...

Page 38: ...dtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le blo...

Page 39: ...gestellten oder benannt Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law ver...

Page 40: ...ur tous les autres appareils lectriques que les produits d sign s par Pulse Secure seulement AC AC UL CSA UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bij het inst...

Page 41: ...Hardware Guide 2018 Pulse Secure LLC All rights reserved 42 Certification Statements Japan A VCCI A Israel Saudi Arabia Complies with the CITC Technical Specification CITC GEN001 IT001 South Korea A...

Page 42: ...PSA3000 Hardware Guide 2018 Pulse Secure LLC All rights reserved 43 Thailand...

Reviews: