background image

i-Flash Technology Limited 

Rm 1110, 11F, Fabrico Industrial 
Buildings, 78 Kwai Cheung Road, 
Kwai Chung, NT. Hong Kong 

Web: 

 

Tel: 

 

Fax: 

 

Email: 

 

www.iflashtec.com 
+852 2110 9587 
+852 3585 5233 
info@iflashtec.com

 

 

 

 

PULSE FXI6 Series Installation Guide 

1 | 

P a g e

 

 

 

 

 

 

PULSE IP Camera User Manual 

Model Number: FXI6 Series 

Summary of Contents for FXI6 Series

Page 1: ...Industrial Buildings 78 Kwai Cheung Road Kwai Chung NT Hong Kong Web Tel Fax Email www iflashtec com 852 2110 9587 852 3585 5233 info iflashtec com PULSE FXI6 Series Installation Guide 1 P a g e PULSE...

Page 2: ...caused if any of the warnings below are neglected Cautions Injury or damage to the equipment may occur if any of the following caution messages are neglected Warnings Follow these safeguards to preven...

Page 3: ...outside the range of 10 C to 50 C when the device is in operation Do not expose the device to damp wet conditions or high electromagnetism radiation To avoid heat accumulation make sure that your ope...

Page 4: ...Welcome 5 Package Contents 6 Product Overview 7 Configuring the FXI6 via Web Browser 10 Access FXI6 Web Configuration Menu 10 Connect The Camera to DHCP server 10 Connect to the Camera using Static IP...

Page 5: ...ering rich image clarity at rapid transmission rates Integrated SIP can pass alarms to the PSTN mobile phones SIP IP phones SIP videophones and enables 2 way VoIP communication The FXI6 ensures ease o...

Page 6: ...g NT Hong Kong Web Tel Fax Email www iflashtec com 852 2110 9587 852 3585 5233 info iflashtec com PULSE FXI6 Series Installation Guide 6 P a g e Package Contents Items in the package FXI6 Series IP Ca...

Page 7: ...x Email www iflashtec com 852 2110 9587 852 3585 5233 info iflashtec com PULSE FXI6 Series Installation Guide 7 P a g e Product Overview FXI6 Series Camera Connectors and Cables With Audio Reset Butto...

Page 8: ...on Response 1 0V lux sec 550nm 1 0V lux sec 550nm 1 0V lux sec 550nm Max Video Resolution 1 600H x 1 200V 1 280H x 960V 2 048H x 1 536V Max Frame Rate 10 fps at 1600 x 1200 25 fps at 1280 x 720 to 240...

Page 9: ...Server Professional Windows XP Windows Vista Windows 7 CPU Intel Pentium 4 or higher 2 GHz RAM 1 GB 4 GB recommended for larger systems Support for DirectX 8 0 and above Using PoE as power supply with...

Page 10: ...eb Configuration Menu Connect the Camera to DHCP server 1 Run the Search tool provided in Software CD 2 Click on button in order to begin device detection 3 The detected devices will appear in the Out...

Page 11: ...ect your PC to the same network as the FXI6 2 Configure the IP address of your PC to 192 168 1 XXX 1 XXX 255 and configure the subnet mask to 255 255 255 0 3 Make sure that the device is turned on and...

Page 12: ...If the motion detection alarm is triggered the indicator will flash red Click on the indicator to turn off the alarm 2 Control Console PTZ Console controller PTZ device needs to be connected not supp...

Page 13: ...the image to fit into the window panel in the home scream 10 Configuration Camera Configuration Setting 11 Language Select language English or Chinese 12 Play Stop Plays Stops the video 13 Capture Ca...

Page 14: ...d time 24h clock Set the System Time Update via NTP Server the camera will obtain the time from an NTP server Specify the NTP server s IP address or host name And you can select your time zone from th...

Page 15: ...87 852 3585 5233 info iflashtec com PULSE FXI6 Series Installation Guide 15 P a g e Device Name Setting This field lets you configure the name of the FXI6 which helps Search and Surveillance Software...

Page 16: ...BR is selected the codec varies the amount of output data per time segment VBR produces a better quality to space ratio The bits available are used to enable more flexibly and encode sound or video da...

Page 17: ...resolution mode while recording a copy via Surveillance System software in high resolution due to the limitation of internet bandwidth In this case for example primary stream can be configured to hav...

Page 18: ...r can also assign the FXI6 an HTTP Port other than 80 IP Address Configuration The FXI6 operates in two modes Dynamically Assigned via DHCP all the field values for the Static IP mode are not used The...

Page 19: ...is changed the port number is needed to access the web GUI for instance http 192 168 1 168 8080 NOTE If the HTTP Port is 80 when you add this device to Surveillance Software the RTSP port is 554 If th...

Page 20: ...Basic Settings DDNS 3 Enter the required information DDNS Active If you want to use DDNS please set this field to Enabled DDNS ISP Type Select your DDNS ISP Type Self Define DDNS Address Self define...

Page 21: ...lashtec com PULSE FXI6 Series Installation Guide 21 P a g e SIP Page The FXI6 has the ability to receive phone calls and make phone calls when an alarm event is triggered through motion detection or a...

Page 22: ...ork ONLY outbound proxies can provide a solution for a symmetric NAT SIP User ID User account information provided by your service provider ITSP this is either an actual phone number or is formatted l...

Page 23: ...page click Basic Settings SIP 2 Go to Phone List Tab 3 Enter the Phone number and name click Add a Number to save all the changes 4 Numbers added to the system will be listed in this page Status Page...

Page 24: ...m Up Time Since This field shows the system up time since the last reboot Network Status MAC Address The device ID in HEXADECIMAL format LAN IP Address This field shows the LAN IP address of the FXI6...

Page 25: ...You can also add and remove users here Existing User Name The field lists all of the current users You can insert or remove users from the list by click on the Add or Update or Delete button User Name...

Page 26: ...ry setting except IP Address Firmware Upgrade and Provisioning Items Upgrade via This field lets you choose the firmware upgrade method The FXI6 supports HTTP HTTPS and TFTP Firmware Server Path The I...

Page 27: ...package and copy the files to the firmware upgrade server directory Upgrades are supported via TFTP HTTP and HTTPS 3 Log in to the Maintenance page of the FXI6 Select the server type from the dropdow...

Page 28: ...password required to log in to your SMTP server for example 123 gmail com 123 SSL Checked if the SMTP server requires a secure connection Test Email Account Settings Click the Test button to send a t...

Page 29: ...s Installation Guide 29 P a g e Path The directory in the FTP server where recorded video will be uploaded Test FTP Account Settings Click the Test button to upload a sample file to make sure that FTP...

Page 30: ...motion detection will be enabled If something somebody moves in the motion detection region an alarm will be triggered Show Motion Detection Regions If this option is selected the motion detection re...

Page 31: ...52 2110 9587 852 3585 5233 info iflashtec com PULSE FXI6 Series Installation Guide 31 P a g e Configure Motion Detection Time Schedule Alarm Actions This section allows you to configure the time durin...

Page 32: ...ide 32 P a g e FXI6 System Log This page is used to set up the system log server path and system log level Once they are correctly configured the device will send out system log messages to the system...

Reviews: