Some reclaim systems are ordered with extra features. This manual covers the most
common ones. If installing something that does not pertain to these three, check the back
of this manual for any site specific diagrams or instructions.
AquaLink (AOS)
The Gen 3 Reclaim is set up for simple and quick installation or retrofit of the AOS-I or the
AOS-II system add-on. Plumb the system as follows: 1) Tape / thread the male adaptor
(supplied) to the recirculation line output as indicated in the picture. 2) Plumb from the
male adaptor to the AOS inlet port (top fitting) 3) Plumb the AOS outlet port (bottom) to the
recirculation line “stub up” on the equipment room floor. There is no wiring required, simply
unscrew the black cover from the AOS receptacle and screw in the yellow cable from the
AOS control box (see photos below). Please note: There is a finder pin in the receptacle
and cable so there is only one way it will screw together. Verify that the pump runs when it
should.
See the appropriate Aqualink Manual for more details!
System Installation - Extras
AOS I receptacle on reclaim control box closed (left)
and open (right)
Yellow cable from AOS I
Recirculation
Line Output
AOS I & II
Male
Adaptor
Note: If an AOS-II option is
ordered - there will be an
additional manifold with a 1” outlet
to supply treated water to the
pump for flushing the bio-balls.
(Reference pg 21 for more details)
AOS II CAT 5 receptacle on the right side of
the reclaim control box and AOS II control
box bottom (right)