Checking Pump Rotation (continued).
Note the rotation check points of the pump
motor shaft as shown to check rotation.
The motor should be rotating clockwise
when looking from the end of the motor
(left side of the machine). There is also
a rotation indicator arrow on the pump
volute.
10 HP Motor
System Start-up (Continued)
3 or 5 HP Motor
If the motor is rotating in the wrong
direction - reverse two of the leads in
the main breaker box or disconnect on
the wall and verify pump rotation is now
correct.
Once pump rotation has been verified,
go back to “Hand Mode” by either the
“F1” button or touching “Hand” option on
the Touch Screen resulting in the screen
shot on the top of the next page.