System Troubleshooting - Minor Fault
Oxygen Concentrator Fault
An “O2 No PSI” fault is a minor fault
that does not shut down the Reclaim.
It does stop ozone output, however. If
the ReclaIm was built with either the12
or 24 gram ozone option, it will have an
oxygen concentrator on board. If the
system was built with the 4 gram ozone
option (or no ozone option at all), there
will not be an oxygen concentrator.
It is an indicator that the pressure
switch inside of the ozone generator is
not satisfied. Refer to page 35 & verify
that the Oxygen Concentrator pressure
gauge on the right side is set at
11.5psi. (Adjustment info on next page)
Also check the flowmeter
on the left side. It should
be around 2-4 with the line
connected.
“Touch” the Yellow Fault Box to
go to next screen. Then “touch”
the “Settings” button on that
screen.