System Troubleshooting - Minor Fault
Ozone Fault - Drive Board Troubleshooting
Red Faullt Light on Solid (No Flashing)
--Replace the Drive Board, the fault light should
always flash if the problem is external to the
board.
Fault Light Flashing Once per Second could
mean:
-
-The blue reaction chamber (cell) is not
receiving enough voltage from the transformer.
--Check the terminal screw on the high voltage
side of the chamber. The screw may be loose
and not making a solid connection. (This is the
white wire that resembles a spark plug wire
from the transformer to the reaction chamber.)
Fault Light Flashing Twice per Second
could mean:
--Transformer is bad: Inspect the transformer
for oil leaking. If oil is found, replace the
transformer.
--Remove the transformer and shake it near
the ear. If water or “sloshing” sound is heard -
replace the transformer.
--Reaction chamber or High Voltage wire is
bad.
--High Voltage wire not making a good
connection. Check at both transformer and
resction chamber. Verify connections are tight.
--Look for evidence of arcing or shorting of high
voltage wire to chassis. Is the wire showing
signs of brown or black “arcing”?
--Reaction Chamber Glass is broken.
Fault Light Flashing Three Times per
Second could mean:
--Thermal Switch on drive board has closed.
System overheating. Generally means cooling
fan failure. Check fan.
--Internal Temp is greater than 140 degrees F.
Cool down unit and check fan for operation and
filter material for blockage.
Ozone LED
Amber
Thermal Switch
Transformer LED
Green
12V LED Green
5amp fuse
Fault LED Red
NOTE: When the ozone generator is
operating correctly, the drive board will
have the amber ozone LED, the green
“Xformer” LED, and the Green 12V LED
all on.
The red Fault LED will be off and the
“System Normal” screen will be on.