JOB NO. _________________________________________________________
•
MODEL NO. ______________________________________________________
•
WATER TEST _____________________________________________________
•
MINERAL TANK SIZE DIA. _______ HEIGHT ________
•
CONTROL VALVE SPECIFICATIONS:
Type of Timer
A) Std
C) 7 Day
B) *L*
D) 12 Day
Day/Time of Backwash
Drain Line Flow Control _____________
gpm
Injector Size _______________________
TYPICAL CONTROL VALVE INFORMATION
Job Specification Sheet
Tank
Dia.
Injector Inj.
Color
Slow Rinse Rate (gpm)
DLFC
***
6”
#0
Red
.31 gpm
1.2 gpm
7”
#0
Red
.31 gpm
1.2 gpm
8”
#1
White
.45 gpm
1.5 gpm
9”
#1
White
.45 gpm
2.0 gpm
10”
#1
White
.45 gpm
2.4 gpm
12”
#2
Blue
.84 gpm
3.5 gpm
13”
#2
Blue
.84 gpm
4.0 gpm
14”
#3
Yellow
1.0 gpm
5.0 gpm
16”
#3
Yellow
1.0 gpm
7.0 gpm
Due to varying water conditions, tank sizes and water pressures, the above settings
should be used only as a guideline.
***
D.L.F.C. (Drain Line Flow Control). Backwash and Rapid Rinse Flow Rates.