10.
(Important!! WE DO NOT recommend connecting adapters to either the yoke or by-
pass valve, while the yoke or bypass valve is connected to the Valve assembly! You
may exert too much pressure on the valve while securing the adapters, causing dam-
age to the valve housing!)
11.
After all soldering is finished and the adapters are securely threaded onto either the
yoke or the brass bypass valve assembly, then attach the yoke or bypass valve back
onto the valve/meter assembly and secure it with the two small stainless steel clamps.
12.
Now position your system in place for the final water line installation.
13.
Remember; if you are using our optional brass bypass valve, make certain the bypass
valve is set in the "Service" position, while soldering the pipes to the system. Then
return it to the "Bypass" position before turning your water back on to the house.
14.
Measure and cut the lengths of pipe you need to plumb the main hard water line into
your system. Then do the same for the clean water line that will exit from the system,
back out into the house.
15.
*NOTE* As you look directly into the two holes in your Fleck valve, the hard water
line will always enter the hole on the LEFT SIDE of the yoke or bypass valve assem-
bly. The valve body also has an arrow stamped into each side, showing the direction
of flow.
16.
If you use our optional bypass valve, arrows indicating water flow direction are
printed on the top of the bypass valve assembly.
17.
Just remember, that as you are looking directly into the two holes where the water
enters and exits the valve, the hard water line from your house always enters the hole
on the LEFT. The conditioned water flowing out from the system, back into your
house is always the hole on the RIGHT.
Installation Cont.
Summary of Contents for PTSF-2510-10
Page 1: ...For Model PTSF 2510 10 PTSF 2510 13 Owners Manual Installation Instructions...
Page 16: ...Timer Assembly Tech Support 1 888 989 7873 PURE WATER TREATMENT INC Page 16...
Page 18: ...Control Valve Drive Assembly Tech Support 1 888 989 7873 PURE WATER TREATMENT INC Page 18...
Page 20: ...Control Valve Base Assembly Tech Support 1 888 989 7873 PURE WATER TREATMENT INC Page 20...