Sea Star Handbuch
8.0 Elektrische Schaltung/
Wiring 12/24V DC with the Option Control Box
Ba ( 10mm Bolzen )
Bei 24V Anlagen ist ein 24-12V Konverter geschaltet
(Nur COMPACT)
A1
Steuerleitung 1 12V Plus
Motor Feed Pump Plus (rot)
A2
Steuerleitung 2
Motor Feed Pump Minus Schwarz
Batterie ,Minus
Steuerleitung
Masse
8.1
Connection of a 230V/50Hz Motor
If you use the system with a 230V 50Hz Motor it is possible to switch ON and OFF with the
Switch at the Panel. However, to use a Relay is always the better Idea. Parts for this
installation could be ordered via us.
8.1.2
12/24V Motor
The 12/24V Motor has a Box on top of the Motor. You have to determine the Po
connection. There is an embossment of + and
– at the bottom. You only can see this if you
use a light.
Reverse connection will result in reverse pump rotation direction and can
damage the pump.
18
12/24 Volt
Batterie
Ein – Aus Schalter
Schaltrelais
Konverter