background image

Follow instructions here, 

in Owner’s Manual, or 

pureAir3000.com/Clean

Clean

1. Unplug purifier. Remove Screw in 

Rear Cover above Power Plug.

2. Remove Rear Cover by prying 

sides loose and tilting up until free.

3. Remove Filter Assembly by 

removing two brass thumbscrews.

Disassemble. Remove dust with running 

water or vacuum. Dry before reassembly.

4. Remove PCO Cell by removing 

two black thumb nuts. Unplug.

Clean with compressed air or vacuum 

(no liquids). Do not disassemble Cell.

5. Remove Activated Oxygen Plate 

by carefully sliding it out of place.

Soak for 12 hours in solution of equal 

parts clear ammonia and water. Dry.

6. Clean Purifier inside and out with 

damp cloth or compressed air.

If necessary, remove Front Grille by 

removing screws at top and tilting out.

7. Ensure all components are dry. 

Reassemble purifier in reverse.

8. Reconnect power and hold 

“Reminder Reset” on Control 

Panel until “Perform Cleaning” 

disappears from Display.