2.
General Informations
Before operating the dehumidifier for the first time, the instruction manual should be carefully studied. After receiving
the unit, you should check your dehumidifier for any damage during transport. In the event of a breakdown, you should
immediately notify the sender.
Transport damage must be declared after unpacking the equipment. You should immediately contact your reseller or
qualified reseller.
Keep the dehumidifier package in a safe place so that it can safely ship it if service is required. To save space, you can
simply cut off the adhesive tape using a knife and fold the cardboard box.
3.
Dehumidifier Functions
This dehumidifier is designed to reduce moisture from the air in a building or part of a building. The purpose is to
prevent damage from moisture, and to dry wet materials such as carpet, floors, walls, furniture, contents, timber, and
building materials. This dehumidifier can prevent formation of condensation, reduce air humidity and keep the desired
relative humidity value constant. The time it takes for the dehumidifier to dry a room and reach the desired relative
humidity depends on the environmental conditions prevailing in the room. For example, the number of changes of air to
the outside, to humidity and room temperature sources can either accelerate or slow the process of dehumidification.
The principle of operation of the dehumidifier, according to the principle of condensation, is achieved with heat
recovery. The fan gets the humid air from the room through a filter and leads it to the evaporator. Here the air is
cooled below the dew point, so that the air of the air of water forms a condensate on the coils that flow into the water
collection vessel. After cooling and drying, the air is again heated by a condenser. By recycling the room air through the
dehumidifier again and again the relative humidity rate of the air is reduced.
4.
Install and Transport
For installation and transport, the following instructions must be followed:
The air inlet and the air outlet must not be covered while the dehumidifier is in operation.
Before any movement, the dehumidifier must be turned off.
For transportation, the dehumidifier should be secured on a flat base to prevent accidents
Empty the water collection tank. The dehumidifier must always be moved vertically
.
If the dehumidifier is in a horizontal position for more than 10 minutes, you should allow it to stand upright for at least
30 minutes before operation. This allows the oil to drain back to the compressor.
5.
Intruction Manual
CAUTION
-
Only operate the dehumidifier in an upright position
.
-
Connect to a standard socket with the correct voltage and current for the unit
.
-
Allow five minutes before restarting when the unit is deactivated for any reason. This will prevent
the compressor from being destroyed. - Check the dehumidifier daily for proper operation.
-
Protect the surfaces from water
.
Please proceed as follows before using this dehumidifier
:
After transporting it to the workplace, it should stand for 30 minutes to lower its fluids
in the compressor. This procedure is recommended to extend the life of the compressor. Plug the plug into
the socket.
Make sure the water tank is in place.
3
[
EN
]
Summary of Contents for DESIGN SERIES PD 130LA
Page 1: ...DESIGN PD 130LA...
Page 2: ......
Page 3: ......
Page 4: ...4 GR...
Page 5: ......
Page 6: ......
Page 8: ......
Page 9: ...9 GR 1 2 14...
Page 10: ...15 ELECTRICAL DIAGRAME DEHUMIDIFIER ELECTRIC WIRING PUMP CONNECTION WIRING OPTION 10 EN...
Page 11: ......
Page 12: ...INDUSTRIAL DEHUMIDIFIER DESIGN SERIES PD 130LA...
Page 21: ...15 ELECTRICAL DIAGRAME DEHUMIDIFIER ELECTRIC WIRING PUMP CONNECTION WIRING OPTION 10 EN...
Page 22: ......