l

 All house exits (windows doors etc) where the dehumidifier is operating, should be shuted. 

l

 Room temperature is below the advised operational range.

l

 There is a kerosene heater or something giving off water vapor in the room.

l

 The room that the device is placed is bigger than suggested.

l

 The humidity level is too high.

The unit makes a loud noise when operating

 

l

 The air iflter is clogged.

l

 The device is tilted instead of being in an upright position.

l

 The floor surface is not flat.

Frost build up on coils

l

 This is normal. This unit is supplied with an Auto defrost feature.

Drain hose water leakage 

l

 Check the correct installation of the drain hose.

l

 Check for any blockage or damage of the drain hose.

Understanding Error and Protection codes
Error Codes:

CL

When the room temperature is below <5°C, the code CL appears. At this state the 

compressor does not work, but the other functions works normally.

LO

When the relative humidity is below 20* RH, the code LO appears. At this state 

the compressor does not work, but the other functions works normally.

HI

When the relative humidity is above 95% RH, the code HU appears. At this state 

both the compressor and the other functions works normally

NOTE: All the pictures in the manual are for explanatory purposes only. The actual 

shape of the unit you purchased may be slightly different, but the operations and 

functions are the same.

In the event of any of the above-mentioned malfunctions, turn 

off the unit, and check for any obstructions. Restart the unit, if 

the malfunction persists, turn off the unit and unplug. Contact 

the manufacturer or a qualified technician for service.

CH- 

When the room temperature is above >38°C, the code CH appears. At this state the

compressor does not work, but the other functions works normally.

E1- 

This  error  code  appear  when  the  temperature  has  been  damaged.  Turn  off  the 

product and contact the technical department of the company immidiately.

E2- 

This error code appear when the humidity sensor has been damaged. Turn off the 

product and contact the technical department of the company immidiately.

1

8

EN

Summary of Contents for PD 12L Design

Page 1: ...USER S MANUAL ENGLISH DEHUMIDIFIER PD 12L Design...

Page 2: ...LANGUAGES ENGLISH 3 23...

Page 3: ...SKED QUESTIONS TROUBLESHOOTING 16 Dear Consumer Congratulations on your choice Puredry s PD12 L Design dehumidifier is distinguished among its class by its excellent performance quite operation and tw...

Page 4: ...it is misplaced or tipped unplug the power cord immediately Make sure the unit is completely dry before resuming oper tion l Disconnect the device if abnormal sounds odors or smoke ccur l If the suppl...

Page 5: ...ample T 3 15A 250V or 350V etc Power o the dehumidi er before removing the plug 3 SOCIABLE REMARKS ENVIRONMENTAL PROTECTION Disposal of equipment no longer used Please follow the instructions below wh...

Page 6: ...se note the SN serial number The SN is labeled on side of the device Please refer to the electronic warranty instructions in the last page English section of this manual 4 STEPS BEFORE USE User s manu...

Page 7: ...els will not fall bellow 5 C 41 F There is a possibility the coils will collect frost at temperatures that are under 5 C 41 F which may result in low performance 3 Ensure the filter is clean 4 Place u...

Page 8: ...Consumption values may vary depending on the relative humidity in the room of operation 30W Consumption during the fan operation The fan only operation is a function that cannot be manually selected I...

Page 9: ...6 GETTING TO KNOW YOUR DEHUMIDIFIER Air Filter Power Cord Air outlet Handle Drain hose outlet Removable water tank Control Panel EN 9...

Page 10: ...on or off The POWER button and the display will turn on The default mode is in sunny mode using the high fan speed UV ION By activating the UV ION positive and negative ions are released to purify the...

Page 11: ...ay shows the current ambient temperature TIMER BUTTON By pressing this button you can set between 1 24 hours of working time When the user sets the time of use it will apear on the display When the se...

Page 12: ...as soon as possible the humidity levels with the lower possible power consumption In any case that the compressor does not start from the beginning lower room humidity that the user sets the product w...

Page 13: ...spilled on the floor Empty the water from the tank and place it again in to the device The water tank must be securely and properly placed for the dehumidifier to operate When the water tank is re in...

Page 14: ...into the drain and make sure that the water flows naturally For correct drainage make sure the hose stays below the level of the drain hose outlet When the continuous drainage feature is not being us...

Page 15: ...ier Do not use abrasive cleaning agents or solvents use a brush or vacuum attachments for cleaning Do not use a dishwasher to clean the filter Do not apply any water directly on or into the device whi...

Page 16: ...e humidity level is essential for your well being and that of your household Extreme fluctuations cause adverse effects on both low humidity may cause respiratory problems and damage on wooden doors w...

Page 17: ...midiifer while operating you may feel that the air coming out of the fan is cooler due to the diffusion reality it is at the same room temperature but with less humidity The unit does not start l Make...

Page 18: ...y is below 20 RH the code LO appears At this state the compressor does not work but the other functions works normally HI When the relative humidity is above 95 RH the code HU appears At this state bo...

Page 19: ...y specialized and certified technicians Does not cover Accidental damage sabotage defects caused by normal wear and tear including wear of consumable parts ie parts that require periodic replacement d...

Page 20: ...submission within thirty 30 days from the date of purchase of the relevant electronic form available on the website https puredryhellas com egg iseis In addition it is possible to post the completed...

Page 21: ...improper transport or packaging when the System is returned to the Dealership or an authorized center Damages caused by service or repairs or other modifications of the System that were not performed...

Page 22: ...the fields as shown below Once the warranty submission has been completed a confirmation message will be sent to your email l Visit our web site and activate your warranty via the below link https www...

Page 23: ...1 24 2 25 3 25 4 26 6 29 7 30 9 33 11 35 10 34 36 PD12L Design 5 28 8 12 39 GR 23...

Page 24: ...1 l 8 l l l l l l l l l 3 l l l l l l l l l l l l l l l l 24 GR...

Page 25: ...24 2 l l l l l l l l PCB T 3 15A 250V 350V 3 l 2002 96 EC 27 2003 l CO2 l A B 25 GR...

Page 26: ...26 SN 4 GR...

Page 27: ...27 1 2 5 C 41 F 5 C 41 F 3 4 2 5 GR 20cm...

Page 28: ...5 PD 12L Design 24 12 V Hz 220 240 50 W 140 165 dB A 37 39 m3 h 120 2 5 x x mm 308 298 563 kg 12 10 m 2 m 1 94 C 5 37 30W smart save energy 140W mode 165W 5 GR 28...

Page 29: ...29 GR 6...

Page 30: ...7 LED DISPLAY HUM SET 5 30 GR ON OFF BUTTON POWER CONT POWER CONT SPEED UV ION UV UV UV UV ION...

Page 31: ...31 GR HUMIDITY SET BUTTON CONT 40 80 5 40 45 50 55 60 65 70 75 80 50 60 CONT 5 HUMSET CONT 5 3 TIMER BUTTON Timer Timer 1 24 00 FAN SPEED HUM SET Cont Cont 30 50...

Page 32: ...32 GR ENERGY SAVING OPERATION smart save energy MODE HUM SET 2 5 2 3 30 5 2 4 30 E Saving 20 LO 1 2 3 15 95 HI...

Page 33: ...GR 8 O 1 33...

Page 34: ...GR 34 2 9 24...

Page 35: ...35 10 l 5 GR...

Page 36: ...GR 36 11 HEPA 50 60...

Page 37: ...GR 37 2 5 Dryer O Dryer l l l l l l l l l l l...

Page 38: ...l l l l l l l l l l l l CL 5 C CH 38 C LO 20 RH HI 95 RH E1 2 38 GR...

Page 39: ...12 GR 39 Silver 2 Puredry Hellas EE Silver Puredry Hellas Puredry...

Page 40: ...40 GR Puredry Puredry Puredry Hellas EE service 15 Platinum 5 Puredry Hellas EE 1 6 2018 Platinum 30 https puredryhellas com egg iseis Manual Puredry Hellas...

Page 41: ...1 6 2018 2 Puredry Puredry Puredry Puredry Hellas EE service 15 GR 41...

Page 42: ...l link https www puredryhellas com egguiseis l email 42 GR...

Reviews: