background image

By  pressing  the  mode  button,  the  user  choose  between  auto  mode  or  dryer  mode.

 

AUTO MODE

In  this  mode  the  relative  humidity  level  is  50%  and  the  fan  operates  at  high  speed 

mode.  Press  the  HUM  set  button  to  adjust  the  relative  humidity  level  to  your 

preference  between  30%  and  80%  by  5%  step  each  time  you  press  the  HUM  set

button. After 5 seconds of inaction the setting is saved.

DRYER MODE

When this function is selected, the fan operates in high speed mode. The user cannot 

change  the  fan  speed  between  LOW  and  HIGH.  During  this  function  the  compressor 

operate  continuously,  despite  the  relative  humidity  level  of  the  room. 

For  drying clothes  place  the  dehumidifier in  a  small  room  nearby  tha  clothes  racand 

close the door. The machine should be at a distance of 40-50cm from the clothes rack 

and not beneath them. For a quick result, clothes should be wringed out good.

Press  this  button  to  set  the  humidity  level.  The  user  can  set  the  level  between 

30%-80% by 5% step . While tha adjustment takes place, the count after 80% returns to 

30%.       30%-35%-40%-45%-50%-55%-60%-65%-70-%-75%-80%-30%-35%....

Press  the  ''Timer''  button  to  set  the  time  which  the  dehumidifier  will  start  or  end  its 

operation. The Timer indicator and the screen will light up. The user can set the time 

between  1-24  hours  with  step  every 

60

  minutes. 

When

  the  timer  set  value  is  "00",  it 

means that the Timer is disabled.

By pressing this button, the SLEEP function is activated. The dehumidifier operates in 

LOW  fan  speed,  and 

keeps

  the  relative  humidity

  levels

  between  57%

-

63%.

  It  is  not 

allowed to change the fan speed or the relative humidity level.

By pressing and holding the SLEEP button, the RESET function is activated. In this way 

the Filter change indicator is reset.

Summary of Contents for PD 2419 Sofia

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...ded safety fuse for overcurrent protection You may find the speciifcations of the fuse marked on the circuit board for example T 3 15A 250V or 350V etc l To connect or disconnect the device hold with...

Page 6: ...Please be sure that the plug that you put the device is grounded Do not use adapter plug...

Page 7: ...For warranty purposes please note the SN serial number The SN is labeled at the rear of the device...

Page 8: ...ration place the device in vertical possition and let it sit for 2 hours to avoid malfunctions 5 Before the initial operation please check if the water level switch located within the water tank area...

Page 9: ...tion 517 2014 EU is enviromental friendly The fan operation cannot be maually selected to operate the fan only It operates automatically during the smart save energy program When the medium or high fa...

Page 10: ......

Page 11: ......

Page 12: ...he relative humidity level of the room When the humidity level is between 45 and 65 the LED color becomes green When the humidity level is above 65 the LED color becomes red When the humidity level is...

Page 13: ...ance of 40 50cm from the clothes rack and not beneath them For a quick result clothes should be wringed out good Press this button to set the humidity level The user can set the level between 30 80 by...

Page 14: ...operating After 30 minutes the fan starts only operating for 5 minutes to check the humidity levels If the humidity increased the dehumidifier starts to operate again both of compressor and fan If not...

Page 15: ...There are two ways to remove collected water Before you empty the water tank make sure that you have turned off and disconected the device from the power supply...

Page 16: ...Turn the unit off and let it sit for one day before storage Clean the removable parts of the device like the water bucket and the air filter...

Page 17: ......

Page 18: ...ith this unit Ask for the original Puredry s filter When the desired humidity level is reached there is a possibility of partial humidity formation on windows This occurs due to the temperature variat...

Page 19: ...sending it back in the area it operates If you are standing near the dehumidiifer while operating you may feel that the air coming out of the fan is cooler due to the diffusion in reality it is at th...

Page 20: ...lative humidity is below 20 C RH the code LO appears At this state the compressor does not work but the other functions works normally E2 This error code appears when the humidity and temperature sens...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...PCB T 3 15A 250V 350V 2002 96 EC 27 2003 CO2...

Page 25: ......

Page 26: ......

Page 27: ...1 20cm 40cm 2 5 C 5 C...

Page 28: ...30 235 12 13 smart save energy 235W Puredry PD2419 Sofia R 290 517 2014...

Page 29: ......

Page 30: ......

Page 31: ...Power Power 50...

Page 32: ...HUM 30 RH 80 RH 5 4 30 35 40 45 50 55 60 65 70 75 80 30 35 MODE Auto mode 50 High HUM 30 RH 80 RH 5 5 Dryer mode HIGH LOW HIGH 40 50 Timer Timer 1 24 1 00...

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ...Hepa Carbon...

Page 37: ......

Page 38: ......

Page 39: ...2...

Page 40: ......

Reviews: