20
Where would it be better to place the dehumidifier?
For optimal results, it is suggested to place the dehumidifier in a central area,
like a hallway. Leave the doors open and the moisture will migrate naturally
towards the device to be processed
Which is the most suitable humidity level?
The suggested humidity range fluctuates between 50% and 60%. This level of an
average humidity ensures the greatest comfort for you and your family,
preventing allergies or diseases, and keeps your home healthy and well
maintained, in terms of plasterboards, dye exfoliation, wood furniture and any
other equipment material that is susceptible to the harmful consequences of
extremely high humidity conditions
Why there is still condensation from the windows, even by using the
dehumidifier?
When the relative humidity> 60% is reached in the room, there is a case that
humidity continues to appear on the windows. This can happen due to the
difference in outside temperature with that of the room. Continue to operate
the dehumidifier and when the outside temperature rises, the windows will be
completely clean.
The dehumidifier is not a heating device. What could be the cause of
warm air being extracted?
The desiccant dehumidifier Rise operates with an electrical resistance that
warms up the desiccant material. As a result, the temperature of the outgoing
air has been increased to 10-12
o
C comparing to the room’s temperature. This
doesn’t denote in any case that this device can be used as a heating appliance
Tank full indicator turns on but the water tank isn’t full. What could
be the cause of it?
When the full tank indicator turns on but the water tank isn’t full, check the
above plastic cover of the water tank. It has to be correctly installed in order the
water level sensor operate normally
The unit doesn’t start
Make sure the dehumidifier’s plug is placed completely into the socket
Check the house fuse/circuit breaker box
Check whether the power cord is damaged
Check the water bucket, if it is full and empty it
Check if the dehumidifier has reached its defined level
Make sure the water bucket is positioned properly
Room temperature is lower or higher than the advised operational
range
Check whether the humidity level has been set in high levels