8.11 Depressurizing the Dryer
8.11.1
Remove Front Panel (see section 8.10.2 )
8.11.2
Pull the ring handle on the
Safety Relief Valve until all
air pressure is released.
8.11.3
To prevent pressure from
building back up, power the
dryer
OFF (See section 8.3
for detail).
8.11.4
Reinstall Front Panel.
8.12 Setting the System Pressure
System 1 & System 2 are adjusted and set independently.
With Compressor running:
8.12.1
Remove Front Panel (see section 8.10.2 )
8.12.2
Pull the Capacity Control Valve
knob out.
8.12.3
Turn the knob until the reading on
the Pressure Gauge is
50 PSI
.
8.12.4
Push the knob in to lock.
8.12.5
Reinstall Front Panel.