Altec AIR
P8400W Air-dryer User’s Guide
Page 56 of 110
P017585 – Rev. A
8.14.3
Pull the Outlet Pressure
Regulator knob out.
8.14.4
Turn knob until Outlet
Pressure (
OUTP
) reading is
at the desired setting.
8.14.5
Push knob in to lock.
8.14.6
Reinstall Front Panel.
8.15 Engaging the Boost Transformer
8.15.1
See section
6.5.13
8.16 Connecting via Web Browser
Warning
The intra-building port (Network/LAN Port) of the equipment is
suitable for connection to intra-building or unexposed wiring or cabling
only. The intra-building port(s) of the equipment MUST NOT be
metallically connected to interfaces that connect to the OSP.
The intra-building port (Network/LAN Port) of the P8400W must use
shielded intra-building cabling/wiring that is grounded at both ends.