Altec AIR
P8400W Air-dryer User’s Guide
Page 30 of 110
P017585 – Rev. A
SYSTEM 2 ONLY
- Runs only System 2 and leaves System 1 in
Standby.
TIME
– The amount of elapsed in the 24-hour cycle
8.5 Identifying Dryer Alarms
8.5.1 High Outlet Pressure Alarm -
Occurs when the Outlet
Pressure (
OUTP
) rises above
the alarm set point for more
than one (1) minute.
(Default setting is 12.0 PSI)
Press the Info (
) Button to
see the detail of the alarm.
See section 13.5 for troubleshooting information.
8.5.2 Low Outlet Pressure Alarm –
Occurs when the Outlet
Pressure (
OUTP
) drops below
the alarm set point for more
than one (1) minute. (Default
setting is 6.5 PSI)
Press the Info (
) Button to
see the detail of the alarm.
See section 13.7 for troubleshooting information.