• Wire directly to or plug the power cord into a
power outlet:
208 - 230, 1 Phase for
P10KW
208 - 230, 3 Phase for
P15KW
9
• Using a medium adjustable wrench,
disconnect tube from the water fi lter.
• Using a funnel (not provided), slowly pour
water into the tube.
10
Prime the Compressor:
CAUTION: The following
steps must be performed
to avoid damage to the
compressor.
• Continue adding water until tube is full.
• Reinstall the tubing to the water fi lter.
• Press down on the quick disconnect fi tting
collar to remove the inlet manifold assembly.
• Set the inlet manifold assembly to the side.
11
• Power the dryer
ON
.
12
• Power the dryer
OFF
.
18
• Power the dryer
ON
.
20
• Let the dryer run until the Humidity drops
under 2%. (May take up to 15 minutes.)
NOTE:
Press
RESET
if the dryer goes into
SHUTDOWN
condition.
17
• Reinstall the inlet manifold assembly by
pressing down on the quick disconnect
fi tting collar and inserting male coupling
fi tting.
16
• Continue adding water until the water level
stabilizes below the Middle Water Sensor.
15
Installation Steps cont.
• Slowly add approximately half a gallon of
water.
13
NOTE:
If water IS being drawn into
the compressor,
Skip to Step #15
If water IS NOT being drawn
into the compressor,
Continue to the Next Step #14
• Power the dryer
OFF
.
14
• Power the dryer
ON
.
Interchange the Compressor
Red & Black Wire Leads:
NOTE: Skip these steps if
water IS being drawn into
the compressor correctly.
• Use the Compressor Connector Tool to
remove the Red & Black wires from the
DRYER SIDE connector.
• Switch the Red & Black wires and re-insert.
• Connect the air supply line(s) to the dryer
Outlet and/or Static Pressure port(s).
CAUTION
: Be careful when removing
plug(s). System may be pressurized.
19