background image

•  Wire directly to or plug the power cord into a 

    power outlet: 

        208 - 230, 1 Phase for 

P10KW

        208 - 230, 3 Phase for 

P15KW

9

•  Using a medium adjustable wrench, 

    disconnect tube from the water fi lter.

•  Using a funnel (not provided), slowly pour 

    water into the tube.

10

Prime the Compressor: 

      CAUTION: The following 

steps must be performed 

to avoid damage to the 

compressor.

•  Continue adding water until tube is full.

•  Reinstall the tubing to the water fi lter.

•  Press down on the quick disconnect fi tting 

    collar to remove the inlet manifold assembly.

•  Set the inlet manifold assembly to the side.

11

•  Power the dryer 

ON

.

12

•  Power the dryer 

OFF

.

18

•  Power the dryer 

ON

.

20

•  Let the dryer run until the Humidity drops

    under 2%. (May take up to 15 minutes.)

NOTE:

 Press 

RESET

 if the dryer goes into 

SHUTDOWN

 condition.

17

•  Reinstall the inlet manifold assembly by 

    pressing down on the quick disconnect 

    fi tting collar and inserting male coupling 

    fi tting.

16

•  Continue adding water until the water level 

    stabilizes below the Middle Water Sensor.

15

Installation Steps cont.

•  Slowly add approximately half a gallon of 

    water.

13

NOTE:

If water IS being drawn into 

the compressor, 

Skip to Step #15

If water IS NOT being drawn 

into the compressor, 

Continue to the Next Step #14

•  Power the dryer 

OFF

.

14

•  Power the dryer 

ON

.

Interchange the Compressor

    Red & Black Wire Leads:

NOTE: Skip these steps if 

water IS being drawn into

the compressor correctly.

•  Use the Compressor Connector Tool to 

    remove the Red & Black wires from the

    DRYER SIDE connector.

•  Switch the Red & Black wires and re-insert.

•  Connect the air supply line(s) to the dryer 

    Outlet and/or Static Pressure port(s).

      CAUTION

: Be careful when removing 

      plug(s). System may be pressurized.

19

Reviews: