Installation Steps cont.

27

•  

REGISTER YOUR DRYER.

        •  Connect alarm hookups (if applicable).

     Please refer to the 

P10KW / P15KW

     User’s Guide

 section on 

Operating Your 

     Dryer

.

Specifi cally, sub-sections:

Connecting to Common Alarm Terminals

Rewiring the Common Alarm Terminals

26

 

•  Visually inspect for water leaks.

 

•  Check for air leaks.

      CAUTION: DO NOT SOAP TEST THE 

HUMIDITY SENSOR FITTING.  DAMAGE 

TO THE SENSOR MAY OCCUR.

With Compressor NOT RUNNING

:

Listen for ‘hissing’ sounds which may indicate a 

fi tting or hose air leak.

With Compressor RUNNING:

Use a 1-inch brush to dab soapy water on all 

air fi ttings and hose connections.

If air bubbles appear, this is an indication that 

air is leaking.

Take steps to seal the leak:

       •  Tighten the fi tting

       •  Re-connect / tighten the

          hose end

       •  Replace the fi tting / 

          hose / component

24

•  Re-install the Front Panel.

25

•  Pull Outlet Pressure Regulator knob 

OUT

.

•  Adjust knob until Outlet Pressure

 (OUTP)

    reading is at the desired setting.

•  Push knob 

IN

 to lock.

23

•  Pull Static Pressure Regulator knob 

OUT

.

•  Adjust knob until the reading on the

    Pressure Gauge is 

17 PSI

.

•  Push knob 

IN

 to lock.

22

             Set the System Pressures:

•  Use this chart to determine the correct Back Pressure and Bypass settings for your local elevation.

•  Unlock the Bypass and Back Pressure Valve

    knobs by loosening the retaining nuts.

21

•  Turn the Bypass Valve (in back) clockwise

    until it is completely closed.

•  Push the Back Pressure Tube 

IN

 towards the

    fi tting.

•  Press and hold the green ferrule 

IN

.

•  Pull Back Pressure Tube out of the fi tting.

•  Adjust the Back Pressure Valve (in front)

    until the 

SYSP

 reading on the Front Panel 

    Display equals the Back Pressure value

    determined earlier in this Step.

•  Re-connect the Back Pressure Tube by 

    pressing it fi rmly into the green ferrule.

•  Adjust the Bypass Valve (in back)

    until the 

SYSP

 reading on the Front Panel 

    Display equals the Bypass Pressure value

    determined earlier in this Step.

•  Lock the Bypass and Back Pressure Valve

    knobs by re-tightening the retaining nuts.

Elevation (Feet)

0

2000

4000

6000

8000 10000 12000

Back Pressure (PSI)

25

24

23

22

21

20

19

Bypass (PSI)

26

25

24

23

22

21

20