6.2 Before You Begin
6.2.1
Carefully inspect the unit, including the shipping box as well as the air
dryer, for ANY DAMAGE CAUSED BY SHIPPING. If any shipping
damage is detected, it is important to file a claim with the shipping
company prior to continuing the installation procedures.
6.2.2
Read the entire
Installing Your Dryer
section to familiarize yourself with
the components and procedures before performing the air dryer installation.
6.2.3
Verify the installation location of the air dryer:
6.2.3.1
Well ventilated and free from abrasive dust or chemicals.
6.2.3.2
Ambient temperature is between 40° and 85° F (optimal).
NOTE:
Higher temperatures will decrease component lifespan.
6.2.3.3
Meets the following power requirements:
15 amp service recommended
110 - 125 VAC
, 50/60 Hz for P1500W, P1500WLP & P1500WHP models
208 - 230 VAC, 50/60 Hz, 1 P
hase for P1502W, P1502WLP &
P1502WHP models
6.2.4
Notify the alarm center of the installation and potential for alarms during
the process (as necessary).
IMPORTANT!
Performing procedures not described in this User’s Guide or installing
components not supplied by ALTEC AIR is NOT RECOMMENDED
AND MAY VOID THE WARRANTY.
WARNING!
High Noise
. ALTEC AIR air dryers are meant to be installed in an
unattended area.