ALTEC AIR, LLC
P1500W Series Air Dryers User’s Guide
Page 17 of 100
P011787 – Rev. S
With Compressor running:
6.5.13.1
Pull the Capacity
Control Valve knob
out.
6.5.13.2
Turn the knob until
the reading on the
pressure gauge is:
80 PSI
for W & WLP
90 PSI
for WHP
NOTE: 90 PSI may be used on
W & WLP dryers in low flow
applications to maintain low
humidity.
6.5.13.3
Push the knob in to
lock.
6.5.14
Let the dryer run until the Humidity drops below 2% (may take up to 15
minutes).
NOTE
: Press the
RESET
Button if the dryer goes into
SHUTDOWN
mode.
6.5.15
Power the dryer
OFF
.