ALTEC AIR, LLC
P1500W Series Air Dryers User’s Guide
Page 18 of 100
P011787 – Rev. S
6.5.16
Remove the Precision Bleed Orifice fitting from the Outlet Port by
pressing the ferrule down
then pulling the fitting
upward.
NOTE:
Save this fitting for use in
low flow applications.
6.5.17
Connect the air supply
line to the Outlet Port.
NOTE:
For all dryers with minimal
FLOW:
Install the included Precision
Bleed Orifice fitting to
maintain a constant air flow.
6.5.18
Power the dryer
ON
.