9.5.6
Use a Voltmeter to measure across the DC terminals.
Should measure
0 VDC
.
9.5.7
Close Front Panel.
If any of the AC voltage measurements are different than indicated above, the
Solid State Relay is defective and should be replaced.
If any of the DC voltage measurements are different that indicated above, the
Control Board may be defective and should be replaced.
See sections 11.1 for part detail and 11.5 for ordering information.
9.6 Testing Consistent Heatless Dryer Cycling
With the Compressor running
:
9.6.1
Open Front Panel (section 8.6 ).
WARNING!
Internal surfaces may be hot
. Use care when coming into contact
with internal components as there is a potential for some of these
components to become hot when in operation or standby.